用于高血压视网膜病变诊断的动静脉速率测量系统

D. Ortiz, M. Cubides, A. Suarez, M. Zequera, J. Quiroga, Jorge A. Gomez, N. Arroyo
{"title":"用于高血压视网膜病变诊断的动静脉速率测量系统","authors":"D. Ortiz, M. Cubides, A. Suarez, M. Zequera, J. Quiroga, Jorge A. Gomez, N. Arroyo","doi":"10.1109/ANDESCON.2010.5633081","DOIUrl":null,"url":null,"abstract":"The retinal blood vessels are very sensitive to the changes in the blood pressure. Those changes are reflected as arteriolar narrowing which changes the vessel caliber, and modify the arterious venous rate (AVR). This is an important indicator of the presence of arterial hypertension, and may be used for the prevention of further consequences caused by the hypertension such as heart attack, brain stroke and renal failure. Through the measure of the vessels caliber, it is possible to get the AVR, a measurement considered as an important sign of the presence of Hypertension. A system is developed for measuring the AVR and determine the presence of Hypertensive Retinopathy and the results are evaluated.","PeriodicalId":359559,"journal":{"name":"2010 IEEE ANDESCON","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"System for measuring the arterious venous rate (AVR) for the diagnosis of Hypertensive Retinopathy\",\"authors\":\"D. Ortiz, M. Cubides, A. Suarez, M. Zequera, J. Quiroga, Jorge A. Gomez, N. Arroyo\",\"doi\":\"10.1109/ANDESCON.2010.5633081\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The retinal blood vessels are very sensitive to the changes in the blood pressure. Those changes are reflected as arteriolar narrowing which changes the vessel caliber, and modify the arterious venous rate (AVR). This is an important indicator of the presence of arterial hypertension, and may be used for the prevention of further consequences caused by the hypertension such as heart attack, brain stroke and renal failure. Through the measure of the vessels caliber, it is possible to get the AVR, a measurement considered as an important sign of the presence of Hypertension. A system is developed for measuring the AVR and determine the presence of Hypertensive Retinopathy and the results are evaluated.\",\"PeriodicalId\":359559,\"journal\":{\"name\":\"2010 IEEE ANDESCON\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 IEEE ANDESCON\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ANDESCON.2010.5633081\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE ANDESCON","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ANDESCON.2010.5633081","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

视网膜血管对血压的变化非常敏感。这些变化反映为小动脉变窄,改变了血管口径,改变了动静脉速率(AVR)。这是动脉高血压存在的重要指标,可用于预防高血压引起的进一步后果,如心脏病发作、脑中风和肾衰竭。通过测量血管口径,可以得到AVR, AVR被认为是高血压存在的重要标志。我们开发了一种测量AVR的系统,用于确定高血压视网膜病变的存在,并对结果进行评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
System for measuring the arterious venous rate (AVR) for the diagnosis of Hypertensive Retinopathy
The retinal blood vessels are very sensitive to the changes in the blood pressure. Those changes are reflected as arteriolar narrowing which changes the vessel caliber, and modify the arterious venous rate (AVR). This is an important indicator of the presence of arterial hypertension, and may be used for the prevention of further consequences caused by the hypertension such as heart attack, brain stroke and renal failure. Through the measure of the vessels caliber, it is possible to get the AVR, a measurement considered as an important sign of the presence of Hypertension. A system is developed for measuring the AVR and determine the presence of Hypertensive Retinopathy and the results are evaluated.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信