{"title":"电力电子应用中厚铜芯有机基板上贴片元件的可靠性研究","authors":"K. Meier, M. Roellig, K. Bock","doi":"10.1109/EUROSIME.2015.7103160","DOIUrl":null,"url":null,"abstract":"In this work we present the results on a reliability study on SMD components mounted on an organic power electronics substrate. The substrate technology has been developed to meet the needs of high ampacity and thermal conductivity with an organic substrate material. Therefore a thick structured copper core was introduced throughout the entire substrate size (see fig. 1). On top of the copper core common FR4 multilayer structures are realised to create a typical SMD PCB surface. The bottom of the copper core was covered with one prepreg with a high thermal conductivity and one copper layer to be able to connect to a heat sink. The copper core becomes structured to enable the use as the layer for conducting high currents. Therefore insulation trenches were manufactured and plugged with a polymer. Introducing a copper core as described changes the thermo-mechanical behaviour of the substrate. Hence, due to the higher stiffness of the copper core PCB, the thermo-mechanical reliability of SMD components can be affected as well. Thermal cycling and shock tests were conducted to reveal the life time of ceramic chip resistors with a size of 0603, 0805 and 1206 in the case of mounting position entirely over the copper core or FR4, over the copper core/FR4 interface or over the copper core insulation trenches (see fig. 2). A specific test board was designed and manufactured (see fig. 3). The achieved results indicate some differences in the reliability of the components depending on the mounting position. In case of component mounting over the copper much higher failure counts have been seen compared to components mounted over FR4 (see fig. 4). Mounting the components on top of the copper core/FR4 interface or insulation trenches changes the reliability in dependence of the component size.","PeriodicalId":250897,"journal":{"name":"2015 16th International Conference on Thermal, Mechanical and Multi-Physics Simulation and Experiments in Microelectronics and Microsystems","volume":"33 8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-04-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Reliability study on SMD components on an organic substrate with a thick copper core for power electronics applications\",\"authors\":\"K. Meier, M. Roellig, K. Bock\",\"doi\":\"10.1109/EUROSIME.2015.7103160\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this work we present the results on a reliability study on SMD components mounted on an organic power electronics substrate. The substrate technology has been developed to meet the needs of high ampacity and thermal conductivity with an organic substrate material. Therefore a thick structured copper core was introduced throughout the entire substrate size (see fig. 1). On top of the copper core common FR4 multilayer structures are realised to create a typical SMD PCB surface. The bottom of the copper core was covered with one prepreg with a high thermal conductivity and one copper layer to be able to connect to a heat sink. The copper core becomes structured to enable the use as the layer for conducting high currents. Therefore insulation trenches were manufactured and plugged with a polymer. Introducing a copper core as described changes the thermo-mechanical behaviour of the substrate. Hence, due to the higher stiffness of the copper core PCB, the thermo-mechanical reliability of SMD components can be affected as well. Thermal cycling and shock tests were conducted to reveal the life time of ceramic chip resistors with a size of 0603, 0805 and 1206 in the case of mounting position entirely over the copper core or FR4, over the copper core/FR4 interface or over the copper core insulation trenches (see fig. 2). A specific test board was designed and manufactured (see fig. 3). The achieved results indicate some differences in the reliability of the components depending on the mounting position. In case of component mounting over the copper much higher failure counts have been seen compared to components mounted over FR4 (see fig. 4). Mounting the components on top of the copper core/FR4 interface or insulation trenches changes the reliability in dependence of the component size.\",\"PeriodicalId\":250897,\"journal\":{\"name\":\"2015 16th International Conference on Thermal, Mechanical and Multi-Physics Simulation and Experiments in Microelectronics and Microsystems\",\"volume\":\"33 8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-04-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 16th International Conference on Thermal, Mechanical and Multi-Physics Simulation and Experiments in Microelectronics and Microsystems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EUROSIME.2015.7103160\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 16th International Conference on Thermal, Mechanical and Multi-Physics Simulation and Experiments in Microelectronics and Microsystems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EUROSIME.2015.7103160","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

在这项工作中,我们提出了安装在有机电力电子衬底上的SMD元件可靠性研究的结果。衬底技术是为了满足有机衬底材料对高电容和高导热性的要求而发展起来的。因此,在整个基板尺寸中引入了厚结构的铜芯(见图1)。在铜芯顶部实现了常见的FR4多层结构,以创建典型的SMD PCB表面。铜芯的底部覆盖有一个具有高导热性的预浸料和一个铜层,以便能够连接到散热器。铜芯的结构使其能够作为导电大电流的层使用。因此,绝缘沟槽被制造出来并用聚合物堵塞。如上所述,引入铜芯会改变衬底的热机械行为。因此,由于铜芯PCB的刚度较高,SMD组件的热机械可靠性也会受到影响。进行了热循环和冲击试验,以揭示尺寸为0603、0805和1206的陶瓷片式电阻在安装位置完全在铜芯或FR4上、在铜芯/FR4接口上或在铜芯绝缘沟槽上的寿命(见图2)。设计并制造了一个特定的测试板(见图3)。所获得的结果表明,根据安装位置的不同,组件的可靠性存在一些差异。与安装在FR4上的组件相比,安装在铜上的组件的故障数量要高得多(见图4)。将组件安装在铜芯/FR4接口或绝缘沟槽的顶部会改变组件尺寸的可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Reliability study on SMD components on an organic substrate with a thick copper core for power electronics applications
In this work we present the results on a reliability study on SMD components mounted on an organic power electronics substrate. The substrate technology has been developed to meet the needs of high ampacity and thermal conductivity with an organic substrate material. Therefore a thick structured copper core was introduced throughout the entire substrate size (see fig. 1). On top of the copper core common FR4 multilayer structures are realised to create a typical SMD PCB surface. The bottom of the copper core was covered with one prepreg with a high thermal conductivity and one copper layer to be able to connect to a heat sink. The copper core becomes structured to enable the use as the layer for conducting high currents. Therefore insulation trenches were manufactured and plugged with a polymer. Introducing a copper core as described changes the thermo-mechanical behaviour of the substrate. Hence, due to the higher stiffness of the copper core PCB, the thermo-mechanical reliability of SMD components can be affected as well. Thermal cycling and shock tests were conducted to reveal the life time of ceramic chip resistors with a size of 0603, 0805 and 1206 in the case of mounting position entirely over the copper core or FR4, over the copper core/FR4 interface or over the copper core insulation trenches (see fig. 2). A specific test board was designed and manufactured (see fig. 3). The achieved results indicate some differences in the reliability of the components depending on the mounting position. In case of component mounting over the copper much higher failure counts have been seen compared to components mounted over FR4 (see fig. 4). Mounting the components on top of the copper core/FR4 interface or insulation trenches changes the reliability in dependence of the component size.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信