J. A. Cortés, F. Cañete, Luis Diez, J. T. Entrambasaguas
{"title":"室内电力线信道响应周期短时变化的表征","authors":"J. A. Cortés, F. Cañete, Luis Diez, J. T. Entrambasaguas","doi":"10.1109/ISPLC.2005.1430524","DOIUrl":null,"url":null,"abstract":"Indoor power-line channels response exhibits a time-varying behaviour with a twofold nature. The first one is the well-known long-term variation caused by the connection and disconnection of electrical devices. The second one is a short-time variation, synchronous to the mains, whose origin is the dependence of the impedance presented by electrical devices on the mains voltage (Canete, FJ et al., 2005). The purpose of this paper is to assess the importance of this latter aspect in actual channels. To this end, a measurement procedure able to extract these short-time variations is described at first. Afterwards, a statistical analysis of the results obtained from a measurement campaign performed at different scenarios is given. Specifically, the delay spread, the peak excursion and the rate of change of the frequency response in the band from 1 MHz to 20 MHz are presented and discussed.","PeriodicalId":153251,"journal":{"name":"International Symposium on Power Line Communications and Its Applications, 2005.","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-04-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"47","resultStr":"{\"title\":\"Characterization of the cyclic short-time variation of indoor power-line channels response\",\"authors\":\"J. A. Cortés, F. Cañete, Luis Diez, J. T. Entrambasaguas\",\"doi\":\"10.1109/ISPLC.2005.1430524\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Indoor power-line channels response exhibits a time-varying behaviour with a twofold nature. The first one is the well-known long-term variation caused by the connection and disconnection of electrical devices. The second one is a short-time variation, synchronous to the mains, whose origin is the dependence of the impedance presented by electrical devices on the mains voltage (Canete, FJ et al., 2005). The purpose of this paper is to assess the importance of this latter aspect in actual channels. To this end, a measurement procedure able to extract these short-time variations is described at first. Afterwards, a statistical analysis of the results obtained from a measurement campaign performed at different scenarios is given. Specifically, the delay spread, the peak excursion and the rate of change of the frequency response in the band from 1 MHz to 20 MHz are presented and discussed.\",\"PeriodicalId\":153251,\"journal\":{\"name\":\"International Symposium on Power Line Communications and Its Applications, 2005.\",\"volume\":\"22 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-04-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"47\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Symposium on Power Line Communications and Its Applications, 2005.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISPLC.2005.1430524\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Symposium on Power Line Communications and Its Applications, 2005.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISPLC.2005.1430524","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 47
摘要
室内电力线信道响应表现出时变特性,具有两面性。第一个是众所周知的由电气设备的连接和断开引起的长期变化。第二种是与市电同步的短时变化,其根源是电气设备呈现的阻抗对市电电压的依赖(Canete, FJ et al., 2005)。本文的目的是评估后一个方面在实际渠道中的重要性。为此,首先描述了一种能够提取这些短时变化的测量程序。然后,对在不同情况下进行的测量活动所获得的结果进行了统计分析。具体地说,给出并讨论了在1 ~ 20 MHz频段内频率响应的延迟扩展、峰值偏移和变化率。
Characterization of the cyclic short-time variation of indoor power-line channels response
Indoor power-line channels response exhibits a time-varying behaviour with a twofold nature. The first one is the well-known long-term variation caused by the connection and disconnection of electrical devices. The second one is a short-time variation, synchronous to the mains, whose origin is the dependence of the impedance presented by electrical devices on the mains voltage (Canete, FJ et al., 2005). The purpose of this paper is to assess the importance of this latter aspect in actual channels. To this end, a measurement procedure able to extract these short-time variations is described at first. Afterwards, a statistical analysis of the results obtained from a measurement campaign performed at different scenarios is given. Specifically, the delay spread, the peak excursion and the rate of change of the frequency response in the band from 1 MHz to 20 MHz are presented and discussed.