自适应供电单元:高效4G宏蜂窝基站解决方案

Jean-Marie Retrouvey, P. Descamps, Philippe Maugars, Nguyen Trieu Luan Le
{"title":"自适应供电单元:高效4G宏蜂窝基站解决方案","authors":"Jean-Marie Retrouvey, P. Descamps, Philippe Maugars, Nguyen Trieu Luan Le","doi":"10.1109/MELCON.2014.6820531","DOIUrl":null,"url":null,"abstract":"As global consumption of mobile network is increasing, 4G base station must be designed in a context of improvement in power efficiency. This article presents a new concept of managing the DC-to-DC converter supplying power amplifiers in base stations, targeting a factor two reduction in power consumption. This new concepts provide new specifications for base stations but also for DC-DC converter. Details of the concept and the practical implementation of a 500 kHz and zero to 112W buck converter are discussed. Losses are analyzed and dynamic response is discussed. The prototype achieves 94% power efficiency and a good stability over the complete power range.","PeriodicalId":103316,"journal":{"name":"MELECON 2014 - 2014 17th IEEE Mediterranean Electrotechnical Conference","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Adaptive power supply unit: A solution for efficient 4G macro-cell base station\",\"authors\":\"Jean-Marie Retrouvey, P. Descamps, Philippe Maugars, Nguyen Trieu Luan Le\",\"doi\":\"10.1109/MELCON.2014.6820531\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"As global consumption of mobile network is increasing, 4G base station must be designed in a context of improvement in power efficiency. This article presents a new concept of managing the DC-to-DC converter supplying power amplifiers in base stations, targeting a factor two reduction in power consumption. This new concepts provide new specifications for base stations but also for DC-DC converter. Details of the concept and the practical implementation of a 500 kHz and zero to 112W buck converter are discussed. Losses are analyzed and dynamic response is discussed. The prototype achieves 94% power efficiency and a good stability over the complete power range.\",\"PeriodicalId\":103316,\"journal\":{\"name\":\"MELECON 2014 - 2014 17th IEEE Mediterranean Electrotechnical Conference\",\"volume\":\"16 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-04-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"MELECON 2014 - 2014 17th IEEE Mediterranean Electrotechnical Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MELCON.2014.6820531\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"MELECON 2014 - 2014 17th IEEE Mediterranean Electrotechnical Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MELCON.2014.6820531","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

随着全球移动网络使用量的不断增加,4G基站的设计必须考虑到功率效率的提高。本文提出了一种管理为基站功率放大器供电的dc - dc转换器的新概念,目标是将功耗降低两倍。这一新概念不仅为基站提供了新的规范,也为DC-DC转换器提供了新的规范。详细讨论了500khz零至112W降压变换器的概念和实际实现。分析了损耗,讨论了动态响应。该样机在整个功率范围内实现了94%的功率效率和良好的稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Adaptive power supply unit: A solution for efficient 4G macro-cell base station
As global consumption of mobile network is increasing, 4G base station must be designed in a context of improvement in power efficiency. This article presents a new concept of managing the DC-to-DC converter supplying power amplifiers in base stations, targeting a factor two reduction in power consumption. This new concepts provide new specifications for base stations but also for DC-DC converter. Details of the concept and the practical implementation of a 500 kHz and zero to 112W buck converter are discussed. Losses are analyzed and dynamic response is discussed. The prototype achieves 94% power efficiency and a good stability over the complete power range.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信