{"title":"POF衰减谱测量方法研究","authors":"Feng Chunyuan, Rao Zhongyang","doi":"10.1109/ICICTA.2011.453","DOIUrl":null,"url":null,"abstract":"Truncation is an efficient way to measure attenuation spectrum of PMMA and PS, and we set up the systems measuring the attenuation of POF. The position of low loss can be discovered, therefore we not only can choose suitable transmission windows and suitable pump sources, but also use wavelength division multiplexing (WDM) to settle bandwidth problem. We analyze the attenuation spectrum and make a comparison between PMMA and PS fiber. Three windows of PMMA are 520nm, 574nm and 650nm. The window at 650nm is usually used. The loss at 520nm, 574nm is smaller and the attenuation spectrum is flatter, so this window will be used better. PS fiber has been found existing six windows. There are 550 nm, 580 nm, 630 nm, 670 nm, 733 nm and 780nm in the range of measurement. Two windows of 550nm and 580nm are suitable for exploring.","PeriodicalId":368130,"journal":{"name":"2011 Fourth International Conference on Intelligent Computation Technology and Automation","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-03-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Research on Measurement of POF Attenuation Spectrum\",\"authors\":\"Feng Chunyuan, Rao Zhongyang\",\"doi\":\"10.1109/ICICTA.2011.453\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Truncation is an efficient way to measure attenuation spectrum of PMMA and PS, and we set up the systems measuring the attenuation of POF. The position of low loss can be discovered, therefore we not only can choose suitable transmission windows and suitable pump sources, but also use wavelength division multiplexing (WDM) to settle bandwidth problem. We analyze the attenuation spectrum and make a comparison between PMMA and PS fiber. Three windows of PMMA are 520nm, 574nm and 650nm. The window at 650nm is usually used. The loss at 520nm, 574nm is smaller and the attenuation spectrum is flatter, so this window will be used better. PS fiber has been found existing six windows. There are 550 nm, 580 nm, 630 nm, 670 nm, 733 nm and 780nm in the range of measurement. Two windows of 550nm and 580nm are suitable for exploring.\",\"PeriodicalId\":368130,\"journal\":{\"name\":\"2011 Fourth International Conference on Intelligent Computation Technology and Automation\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-03-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 Fourth International Conference on Intelligent Computation Technology and Automation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICICTA.2011.453\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 Fourth International Conference on Intelligent Computation Technology and Automation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICICTA.2011.453","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Research on Measurement of POF Attenuation Spectrum
Truncation is an efficient way to measure attenuation spectrum of PMMA and PS, and we set up the systems measuring the attenuation of POF. The position of low loss can be discovered, therefore we not only can choose suitable transmission windows and suitable pump sources, but also use wavelength division multiplexing (WDM) to settle bandwidth problem. We analyze the attenuation spectrum and make a comparison between PMMA and PS fiber. Three windows of PMMA are 520nm, 574nm and 650nm. The window at 650nm is usually used. The loss at 520nm, 574nm is smaller and the attenuation spectrum is flatter, so this window will be used better. PS fiber has been found existing six windows. There are 550 nm, 580 nm, 630 nm, 670 nm, 733 nm and 780nm in the range of measurement. Two windows of 550nm and 580nm are suitable for exploring.