{"title":"超细颗粒类型对超高强混凝土性能的影响","authors":"S. Rols, M. Mbessa, J. Ambroise, J. Pera","doi":"10.14359/5584","DOIUrl":null,"url":null,"abstract":"Very-high strength concrete (>100 MPa) has been developed using different types of ultra-fine particles: silica fume, ground granulated blast-furnace slag, metakaolin, and cristobalite. The effect of the type of ultra-fine particle on some engineering properties of concrete has been investigated: compressive strength, loss of workability and plastic shrinkage. The highest level of strength (120 MPa) was obtained using either 20% slag, or 10% metakaolin, in addition to cement. The workability was maintained for one hour when slag or cristobalite were present in the mixture. The tests undertaken on plastic shrinkage pointed out that very-high strength concrete developed high plastic shrinkage, specially when pozzolans were used. The use of slag does not affect the plastic shrinkage.","PeriodicalId":299049,"journal":{"name":"SP-186: High-Performance Concrete: Performance and Quality of Concrete Structures","volume":"32 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"Influence of Ultra-Fine Particle-Type on Properties of Very High-Strength Concrete\",\"authors\":\"S. Rols, M. Mbessa, J. Ambroise, J. Pera\",\"doi\":\"10.14359/5584\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Very-high strength concrete (>100 MPa) has been developed using different types of ultra-fine particles: silica fume, ground granulated blast-furnace slag, metakaolin, and cristobalite. The effect of the type of ultra-fine particle on some engineering properties of concrete has been investigated: compressive strength, loss of workability and plastic shrinkage. The highest level of strength (120 MPa) was obtained using either 20% slag, or 10% metakaolin, in addition to cement. The workability was maintained for one hour when slag or cristobalite were present in the mixture. The tests undertaken on plastic shrinkage pointed out that very-high strength concrete developed high plastic shrinkage, specially when pozzolans were used. The use of slag does not affect the plastic shrinkage.\",\"PeriodicalId\":299049,\"journal\":{\"name\":\"SP-186: High-Performance Concrete: Performance and Quality of Concrete Structures\",\"volume\":\"32 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"SP-186: High-Performance Concrete: Performance and Quality of Concrete Structures\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14359/5584\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"SP-186: High-Performance Concrete: Performance and Quality of Concrete Structures","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14359/5584","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Influence of Ultra-Fine Particle-Type on Properties of Very High-Strength Concrete
Very-high strength concrete (>100 MPa) has been developed using different types of ultra-fine particles: silica fume, ground granulated blast-furnace slag, metakaolin, and cristobalite. The effect of the type of ultra-fine particle on some engineering properties of concrete has been investigated: compressive strength, loss of workability and plastic shrinkage. The highest level of strength (120 MPa) was obtained using either 20% slag, or 10% metakaolin, in addition to cement. The workability was maintained for one hour when slag or cristobalite were present in the mixture. The tests undertaken on plastic shrinkage pointed out that very-high strength concrete developed high plastic shrinkage, specially when pozzolans were used. The use of slag does not affect the plastic shrinkage.