T. Bouaouiche, Y. Abdelli, M. Machmoum, J. Le Claire
{"title":"并联有源滤波器定频与谐振电流控制器之比较","authors":"T. Bouaouiche, Y. Abdelli, M. Machmoum, J. Le Claire","doi":"10.1109/ICHQP.2004.1409411","DOIUrl":null,"url":null,"abstract":"Two control approaches for three-phase shunt active power filter are investigated and evaluated. Constant-frequency sliding-mode and resonant current controllers are designed. Suitable criterions based on total harmonic distortion, the distribution of current harmonics in different frequency range and the time response of the system under transient conditions are adopted and used to compare the performances of both controllers.","PeriodicalId":406398,"journal":{"name":"2004 11th International Conference on Harmonics and Quality of Power (IEEE Cat. No.04EX951)","volume":"182 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A comparison between fixed-frequency and resonant current controllers for shunt active filters\",\"authors\":\"T. Bouaouiche, Y. Abdelli, M. Machmoum, J. Le Claire\",\"doi\":\"10.1109/ICHQP.2004.1409411\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Two control approaches for three-phase shunt active power filter are investigated and evaluated. Constant-frequency sliding-mode and resonant current controllers are designed. Suitable criterions based on total harmonic distortion, the distribution of current harmonics in different frequency range and the time response of the system under transient conditions are adopted and used to compare the performances of both controllers.\",\"PeriodicalId\":406398,\"journal\":{\"name\":\"2004 11th International Conference on Harmonics and Quality of Power (IEEE Cat. No.04EX951)\",\"volume\":\"182 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-09-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2004 11th International Conference on Harmonics and Quality of Power (IEEE Cat. No.04EX951)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHQP.2004.1409411\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2004 11th International Conference on Harmonics and Quality of Power (IEEE Cat. No.04EX951)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHQP.2004.1409411","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A comparison between fixed-frequency and resonant current controllers for shunt active filters
Two control approaches for three-phase shunt active power filter are investigated and evaluated. Constant-frequency sliding-mode and resonant current controllers are designed. Suitable criterions based on total harmonic distortion, the distribution of current harmonics in different frequency range and the time response of the system under transient conditions are adopted and used to compare the performances of both controllers.