{"title":"稳定离子计在Axcelis GSD植入物中的剂量再现性","authors":"R. C. Johnson, R. Tysinger","doi":"10.1109/IIT.2002.1258012","DOIUrl":null,"url":null,"abstract":"Long-term dose reproducibility and tool to tool dose matching in the Axcelis GSD end-station is critically dependent on process chamber pressure measurement and Pressure Compensation factor selection. Pressure Compensation factor (PCOMP) determination is well established. Pressure measurement in the GSD end-station depends on accurate, repeatable gauge capability: incorrect pressure measurements directly lead to dose errors. For example, the dose equation using PCOMP tells us that for a modest PCOMP value of 30%, a chamber pressure measurement error of 2E-5 torr can result in a dose error up to 6% at normal process pressures. The original HCIG used for pressure measurement was not capable of meeting the requirements for good dose control since gauge to gauge differences were not controlled and gauge accuracy was only on the order of 25%. Axcelis introduced the Granville-Phillips 360 Stabil-Ion gauge to improve dose reproducibility through much improved gauge to gauge matching (+/-6%) and more accurate gauge output. This paper discusses the details of the care and feeding of the Stabil-Ion gauge system and its impact on process dose and process trends.","PeriodicalId":305062,"journal":{"name":"Ion Implantation Technology. 2002. Proceedings of the 14th International Conference on","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Dose reproducibility in Axcelis GSD implanters using Stabil-Ion gauge\",\"authors\":\"R. C. Johnson, R. Tysinger\",\"doi\":\"10.1109/IIT.2002.1258012\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Long-term dose reproducibility and tool to tool dose matching in the Axcelis GSD end-station is critically dependent on process chamber pressure measurement and Pressure Compensation factor selection. Pressure Compensation factor (PCOMP) determination is well established. Pressure measurement in the GSD end-station depends on accurate, repeatable gauge capability: incorrect pressure measurements directly lead to dose errors. For example, the dose equation using PCOMP tells us that for a modest PCOMP value of 30%, a chamber pressure measurement error of 2E-5 torr can result in a dose error up to 6% at normal process pressures. The original HCIG used for pressure measurement was not capable of meeting the requirements for good dose control since gauge to gauge differences were not controlled and gauge accuracy was only on the order of 25%. Axcelis introduced the Granville-Phillips 360 Stabil-Ion gauge to improve dose reproducibility through much improved gauge to gauge matching (+/-6%) and more accurate gauge output. This paper discusses the details of the care and feeding of the Stabil-Ion gauge system and its impact on process dose and process trends.\",\"PeriodicalId\":305062,\"journal\":{\"name\":\"Ion Implantation Technology. 2002. Proceedings of the 14th International Conference on\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ion Implantation Technology. 2002. Proceedings of the 14th International Conference on\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IIT.2002.1258012\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ion Implantation Technology. 2002. Proceedings of the 14th International Conference on","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IIT.2002.1258012","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

Axcelis GSD端站的长期剂量可重复性和工具对工具的剂量匹配关键取决于工艺室压力测量和压力补偿因子的选择。压力补偿系数(PCOMP)的测定方法已经建立。GSD端站的压力测量依赖于精确的、可重复的测量能力:不正确的压力测量直接导致剂量误差。例如,使用PCOMP的剂量方程告诉我们,对于适度的PCOMP值为30%,在正常工艺压力下,室压测量误差为2E-5 torr会导致剂量误差高达6%。原来用于压力测量的HCIG,由于没有控制量规之间的差异,量规精度只有25%左右,不能满足良好的剂量控制要求。Axcelis推出了Granville-Phillips 360稳定离子计,通过改进的计与计匹配(+/-6%)和更精确的计输出,提高了剂量再现性。本文讨论了稳定离子计系统的护理和加料的细节及其对工艺剂量和工艺趋势的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Dose reproducibility in Axcelis GSD implanters using Stabil-Ion gauge
Long-term dose reproducibility and tool to tool dose matching in the Axcelis GSD end-station is critically dependent on process chamber pressure measurement and Pressure Compensation factor selection. Pressure Compensation factor (PCOMP) determination is well established. Pressure measurement in the GSD end-station depends on accurate, repeatable gauge capability: incorrect pressure measurements directly lead to dose errors. For example, the dose equation using PCOMP tells us that for a modest PCOMP value of 30%, a chamber pressure measurement error of 2E-5 torr can result in a dose error up to 6% at normal process pressures. The original HCIG used for pressure measurement was not capable of meeting the requirements for good dose control since gauge to gauge differences were not controlled and gauge accuracy was only on the order of 25%. Axcelis introduced the Granville-Phillips 360 Stabil-Ion gauge to improve dose reproducibility through much improved gauge to gauge matching (+/-6%) and more accurate gauge output. This paper discusses the details of the care and feeding of the Stabil-Ion gauge system and its impact on process dose and process trends.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信