{"title":"存储荧光粉成像板探测量子效率:蒙特卡罗研究与实验结果","authors":"G. Barnea","doi":"10.1109/PPC.2003.1277666","DOIUrl":null,"url":null,"abstract":"The performance of an X-ray imaging detector is generally evaluated by considering its detective quantum efficiency (DQE), which measures the ability of the detector to preserve the image information contained in the incident X-ray fluence. The DQE is also an important factor in figures-of-merit used to compare the performance of various radiographic machines and experimental setups. A simple expression is derived for the DQE of a storage-phosphor imaging plate (SPIP) and it is calculated as a function of the incident X-ray energy. The results are compared with measured data acquired from exposing the SPIP to Co/sup 60/ gamma radiation. An excellent agreement with theory is obtained.","PeriodicalId":143385,"journal":{"name":"Digest of Technical Papers. PPC-2003. 14th IEEE International Pulsed Power Conference (IEEE Cat. No.03CH37472)","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-06-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Detective quantum efficiency of a storage phosphor imaging plate: Monte Carlo study and experimental results\",\"authors\":\"G. Barnea\",\"doi\":\"10.1109/PPC.2003.1277666\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The performance of an X-ray imaging detector is generally evaluated by considering its detective quantum efficiency (DQE), which measures the ability of the detector to preserve the image information contained in the incident X-ray fluence. The DQE is also an important factor in figures-of-merit used to compare the performance of various radiographic machines and experimental setups. A simple expression is derived for the DQE of a storage-phosphor imaging plate (SPIP) and it is calculated as a function of the incident X-ray energy. The results are compared with measured data acquired from exposing the SPIP to Co/sup 60/ gamma radiation. An excellent agreement with theory is obtained.\",\"PeriodicalId\":143385,\"journal\":{\"name\":\"Digest of Technical Papers. PPC-2003. 14th IEEE International Pulsed Power Conference (IEEE Cat. No.03CH37472)\",\"volume\":\"21 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-06-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Digest of Technical Papers. PPC-2003. 14th IEEE International Pulsed Power Conference (IEEE Cat. No.03CH37472)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PPC.2003.1277666\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digest of Technical Papers. PPC-2003. 14th IEEE International Pulsed Power Conference (IEEE Cat. No.03CH37472)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PPC.2003.1277666","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Detective quantum efficiency of a storage phosphor imaging plate: Monte Carlo study and experimental results
The performance of an X-ray imaging detector is generally evaluated by considering its detective quantum efficiency (DQE), which measures the ability of the detector to preserve the image information contained in the incident X-ray fluence. The DQE is also an important factor in figures-of-merit used to compare the performance of various radiographic machines and experimental setups. A simple expression is derived for the DQE of a storage-phosphor imaging plate (SPIP) and it is calculated as a function of the incident X-ray energy. The results are compared with measured data acquired from exposing the SPIP to Co/sup 60/ gamma radiation. An excellent agreement with theory is obtained.