{"title":"FTTH-PON网管工具:SANTAD","authors":"N. Chuan, M. Ab-Rahman, A. Premadi, K. Jumari","doi":"10.1109/CITISIA.2009.5224193","DOIUrl":null,"url":null,"abstract":"This paper proposed a network management software tool named Smart Access Network _ Testing, Analyzing and Database (SANTAD) that associated with remotely controlling, optical monitoring, system analyzing, fault detection, protection switching, and automatic recovery apparatus for fiber-to-the-home passive optical network (FTTH-PON) based on Visual Basic programming. The developed program is able to prevent and detect any occurrence of fault in the network system through centralized monitoring and remote operating from central office (CO) via Ethernet connection. SANTAD enable the status of each transmission link to be displayed on a single computer screen with capability to configure the drastic drop of optical signal level and detect the failure simultaneously. The analysis results will then stored in database with certain attributes such as date and time, network failure rate, failure location, etc. The database system enable the history of network scanning process be analyzed and studied by the engineers.","PeriodicalId":144722,"journal":{"name":"2009 Innovative Technologies in Intelligent Systems and Industrial Applications","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-07-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Network management software tool for FTTH-PON: SANTAD\",\"authors\":\"N. Chuan, M. Ab-Rahman, A. Premadi, K. Jumari\",\"doi\":\"10.1109/CITISIA.2009.5224193\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposed a network management software tool named Smart Access Network _ Testing, Analyzing and Database (SANTAD) that associated with remotely controlling, optical monitoring, system analyzing, fault detection, protection switching, and automatic recovery apparatus for fiber-to-the-home passive optical network (FTTH-PON) based on Visual Basic programming. The developed program is able to prevent and detect any occurrence of fault in the network system through centralized monitoring and remote operating from central office (CO) via Ethernet connection. SANTAD enable the status of each transmission link to be displayed on a single computer screen with capability to configure the drastic drop of optical signal level and detect the failure simultaneously. The analysis results will then stored in database with certain attributes such as date and time, network failure rate, failure location, etc. The database system enable the history of network scanning process be analyzed and studied by the engineers.\",\"PeriodicalId\":144722,\"journal\":{\"name\":\"2009 Innovative Technologies in Intelligent Systems and Industrial Applications\",\"volume\":\"4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-07-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 Innovative Technologies in Intelligent Systems and Industrial Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CITISIA.2009.5224193\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 Innovative Technologies in Intelligent Systems and Industrial Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CITISIA.2009.5224193","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文提出了一种基于Visual Basic编程的光纤到户无源光网络(FTTH-PON)远程控制、光监测、系统分析、故障检测、保护切换和自动恢复装置的网络管理软件工具——智能接入网测试、分析和数据库(SANTAD)。所开发的程序能够通过中央办公室(CO)通过以太网连接进行集中监控和远程操作,预防和检测网络系统中任何故障的发生。SANTAD使每个传输链路的状态显示在单个计算机屏幕上,具有配置光信号电平急剧下降和同时检测故障的能力。然后,分析结果将以特定属性(如日期和时间、网络故障率、故障位置等)存储在数据库中。数据库系统使工程师能够对网络扫描过程的历史进行分析和研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Network management software tool for FTTH-PON: SANTAD
This paper proposed a network management software tool named Smart Access Network _ Testing, Analyzing and Database (SANTAD) that associated with remotely controlling, optical monitoring, system analyzing, fault detection, protection switching, and automatic recovery apparatus for fiber-to-the-home passive optical network (FTTH-PON) based on Visual Basic programming. The developed program is able to prevent and detect any occurrence of fault in the network system through centralized monitoring and remote operating from central office (CO) via Ethernet connection. SANTAD enable the status of each transmission link to be displayed on a single computer screen with capability to configure the drastic drop of optical signal level and detect the failure simultaneously. The analysis results will then stored in database with certain attributes such as date and time, network failure rate, failure location, etc. The database system enable the history of network scanning process be analyzed and studied by the engineers.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信