电力设备全过程动态状态矢量评估方法:基于状态评估的新颖必要技术途径

Yang Liu, Weidong Qi, Jingfeng Wu, L. Pu, Sen Wang, Yanhua Han, Chuankai Yang, Lin Cheng, Wei Liu, Xu Li, Liangshu Li, Yiqing Shi
{"title":"电力设备全过程动态状态矢量评估方法:基于状态评估的新颖必要技术途径","authors":"Yang Liu, Weidong Qi, Jingfeng Wu, L. Pu, Sen Wang, Yanhua Han, Chuankai Yang, Lin Cheng, Wei Liu, Xu Li, Liangshu Li, Yiqing Shi","doi":"10.1109/CATCON.2017.8280241","DOIUrl":null,"url":null,"abstract":"Deficiencies of current condition assessment method were described and next generation of Dynamic Condition Vector (DCV) assessment method was introduced at first. Typical structure and common operation of combination and expansion of DCV was illustrated by models and examples. Novel and necessary conception of dynamic element, dynamic operator and quasi-matrix operator was introduced with typical structural examples. Several prototypes of DCV for transformer, circuit-breaker, isolator, transmission line and cable were given. Finally, DCV assessment application in overall process was demonstrated. Overall process barrier was analyzed. Comparisons in assessment mathematical procedure and boundary condition limitation between current assessment method and DCV assessment method were made.","PeriodicalId":250717,"journal":{"name":"2017 3rd International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"45 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Dynamic condition vector assessment method for electric power equipment of overall process: Novel and necessary technical approach of condition-based-assessment\",\"authors\":\"Yang Liu, Weidong Qi, Jingfeng Wu, L. Pu, Sen Wang, Yanhua Han, Chuankai Yang, Lin Cheng, Wei Liu, Xu Li, Liangshu Li, Yiqing Shi\",\"doi\":\"10.1109/CATCON.2017.8280241\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Deficiencies of current condition assessment method were described and next generation of Dynamic Condition Vector (DCV) assessment method was introduced at first. Typical structure and common operation of combination and expansion of DCV was illustrated by models and examples. Novel and necessary conception of dynamic element, dynamic operator and quasi-matrix operator was introduced with typical structural examples. Several prototypes of DCV for transformer, circuit-breaker, isolator, transmission line and cable were given. Finally, DCV assessment application in overall process was demonstrated. Overall process barrier was analyzed. Comparisons in assessment mathematical procedure and boundary condition limitation between current assessment method and DCV assessment method were made.\",\"PeriodicalId\":250717,\"journal\":{\"name\":\"2017 3rd International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)\",\"volume\":\"45 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 3rd International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CATCON.2017.8280241\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 3rd International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CATCON.2017.8280241","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

阐述了当前状态评估方法的不足,介绍了新一代动态状态向量(DCV)评估方法。通过模型和实例说明了DCV组合扩展的典型结构和常用操作。结合典型结构实例,介绍了动态元、动态算符和拟矩阵算符等新颖而必要的概念。给出了变压器、断路器、隔离器、输电线路和电缆用直流直流电路的几种样机。最后,演示了DCV评估在整个过程中的应用。分析了整体过程障碍。比较了现有评价方法与DCV评价方法在评价数学过程和边界条件限制方面的差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Dynamic condition vector assessment method for electric power equipment of overall process: Novel and necessary technical approach of condition-based-assessment
Deficiencies of current condition assessment method were described and next generation of Dynamic Condition Vector (DCV) assessment method was introduced at first. Typical structure and common operation of combination and expansion of DCV was illustrated by models and examples. Novel and necessary conception of dynamic element, dynamic operator and quasi-matrix operator was introduced with typical structural examples. Several prototypes of DCV for transformer, circuit-breaker, isolator, transmission line and cable were given. Finally, DCV assessment application in overall process was demonstrated. Overall process barrier was analyzed. Comparisons in assessment mathematical procedure and boundary condition limitation between current assessment method and DCV assessment method were made.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信