小充电率局部放电校准器的验证

R. Procházka, J. Hlavacek
{"title":"小充电率局部放电校准器的验证","authors":"R. Procházka, J. Hlavacek","doi":"10.1109/EPE58302.2023.10149257","DOIUrl":null,"url":null,"abstract":"Partial discharge measurement is one of the standard tools for diagnosing the state of high-voltage insulation systems. Before the measurement, it is necessary to calibrate the entire circuit using a calibrator that generates an accurate charge value. There are now emerging requirements to increase the verification accuracy of these calibrators for charge values less than a few pC. In this paper, a comparison is made between two possible calibration procedures, namely the numerical integration method and the procedure using special charge-sensitive amplifiers. The comparison is made based on uncertainty analysis and practical laboratory measurements. The results show that the use of charge-sensitive amplifiers brings a significant reduction of the calibration uncertainty in the small charge region.","PeriodicalId":210548,"journal":{"name":"2023 23rd International Scientific Conference on Electric Power Engineering (EPE)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Validation of partial discharge calibrators for small charge rates\",\"authors\":\"R. Procházka, J. Hlavacek\",\"doi\":\"10.1109/EPE58302.2023.10149257\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Partial discharge measurement is one of the standard tools for diagnosing the state of high-voltage insulation systems. Before the measurement, it is necessary to calibrate the entire circuit using a calibrator that generates an accurate charge value. There are now emerging requirements to increase the verification accuracy of these calibrators for charge values less than a few pC. In this paper, a comparison is made between two possible calibration procedures, namely the numerical integration method and the procedure using special charge-sensitive amplifiers. The comparison is made based on uncertainty analysis and practical laboratory measurements. The results show that the use of charge-sensitive amplifiers brings a significant reduction of the calibration uncertainty in the small charge region.\",\"PeriodicalId\":210548,\"journal\":{\"name\":\"2023 23rd International Scientific Conference on Electric Power Engineering (EPE)\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-05-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 23rd International Scientific Conference on Electric Power Engineering (EPE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPE58302.2023.10149257\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 23rd International Scientific Conference on Electric Power Engineering (EPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPE58302.2023.10149257","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

局部放电测量是诊断高压绝缘系统状态的标准工具之一。在测量之前,有必要使用产生准确电荷值的校准器校准整个电路。现在有新的要求,以提高这些校准器的验证精度,电荷值小于几个pC。本文比较了两种可能的校准方法,即数值积分法和使用特殊电荷敏感放大器的校准方法。在不确定度分析和实验室实测的基础上进行了比较。结果表明,电荷敏感放大器的使用显著降低了小电荷区域的校准不确定度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Validation of partial discharge calibrators for small charge rates
Partial discharge measurement is one of the standard tools for diagnosing the state of high-voltage insulation systems. Before the measurement, it is necessary to calibrate the entire circuit using a calibrator that generates an accurate charge value. There are now emerging requirements to increase the verification accuracy of these calibrators for charge values less than a few pC. In this paper, a comparison is made between two possible calibration procedures, namely the numerical integration method and the procedure using special charge-sensitive amplifiers. The comparison is made based on uncertainty analysis and practical laboratory measurements. The results show that the use of charge-sensitive amplifiers brings a significant reduction of the calibration uncertainty in the small charge region.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信