{"title":"非理想市电电压下三相有源电力滤波器的控制方法","authors":"M. Machmoum, N. Bruyant","doi":"10.1109/ICPST.2000.898214","DOIUrl":null,"url":null,"abstract":"In this paper, the control algorithms for a three-phase three-wired shunt active power filter under distorted or unbalanced mains voltages conditions are analysed. According to the compensation objectives, a direct method, based on the power balance concept is used and compared to the standard pq algorithm. It allows to impose systematically sinusoidal mains currents in phase with the balanced symmetrical positive sequence system of the supply voltages in spite of mains or load asymmetries. Simulation and experimental results are presented to validate the proposed algorithm and to prove the effectiveness of the design and control strategy.","PeriodicalId":330989,"journal":{"name":"PowerCon 2000. 2000 International Conference on Power System Technology. Proceedings (Cat. No.00EX409)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":"{\"title\":\"Control methods for three-phase active power filters under non-ideal mains voltages\",\"authors\":\"M. Machmoum, N. Bruyant\",\"doi\":\"10.1109/ICPST.2000.898214\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, the control algorithms for a three-phase three-wired shunt active power filter under distorted or unbalanced mains voltages conditions are analysed. According to the compensation objectives, a direct method, based on the power balance concept is used and compared to the standard pq algorithm. It allows to impose systematically sinusoidal mains currents in phase with the balanced symmetrical positive sequence system of the supply voltages in spite of mains or load asymmetries. Simulation and experimental results are presented to validate the proposed algorithm and to prove the effectiveness of the design and control strategy.\",\"PeriodicalId\":330989,\"journal\":{\"name\":\"PowerCon 2000. 2000 International Conference on Power System Technology. Proceedings (Cat. No.00EX409)\",\"volume\":\"24 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-12-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"PowerCon 2000. 2000 International Conference on Power System Technology. Proceedings (Cat. No.00EX409)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPST.2000.898214\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"PowerCon 2000. 2000 International Conference on Power System Technology. Proceedings (Cat. No.00EX409)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPST.2000.898214","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Control methods for three-phase active power filters under non-ideal mains voltages
In this paper, the control algorithms for a three-phase three-wired shunt active power filter under distorted or unbalanced mains voltages conditions are analysed. According to the compensation objectives, a direct method, based on the power balance concept is used and compared to the standard pq algorithm. It allows to impose systematically sinusoidal mains currents in phase with the balanced symmetrical positive sequence system of the supply voltages in spite of mains or load asymmetries. Simulation and experimental results are presented to validate the proposed algorithm and to prove the effectiveness of the design and control strategy.