M. Othman, N. Baharuddin, H. Sulaiman, M. M. Ismail, M. H. Misran, R. Ramlee, M. A. Meor Said, M. Aminuddin, I. Mustaffa, R. A. Rahim, M. N. S. Zainudin, S. A. Anas
{"title":"微波多普勒技术对生命体征的分析","authors":"M. Othman, N. Baharuddin, H. Sulaiman, M. M. Ismail, M. H. Misran, R. Ramlee, M. A. Meor Said, M. Aminuddin, I. Mustaffa, R. A. Rahim, M. N. S. Zainudin, S. A. Anas","doi":"10.1109/ISTMET.2014.6936558","DOIUrl":null,"url":null,"abstract":"This paper presents a system for hearbeat detection using microwave Doppler technique. Using a vector network analyzer, a microwave system is tested for the detection of the heartbeat signal at a distance of 1 feet from a person. The proposed system shows the ability of detecting the heartbeat signals with the possibility of tuning the radiated power. Measurements are performed at 10dbm, 0dbm, -10dbm, -15dbm and -25dbm. Based on measurements perform for respiration and heart beatings, a signal representing the cardiopulmonary activity is presented. The heartbeat rate and heart rate are extracted from the signal using wavelet and classic filters.","PeriodicalId":364834,"journal":{"name":"2014 International Symposium on Technology Management and Emerging Technologies","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-05-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"An analysis of vital sign using microwave Doppler technique\",\"authors\":\"M. Othman, N. Baharuddin, H. Sulaiman, M. M. Ismail, M. H. Misran, R. Ramlee, M. A. Meor Said, M. Aminuddin, I. Mustaffa, R. A. Rahim, M. N. S. Zainudin, S. A. Anas\",\"doi\":\"10.1109/ISTMET.2014.6936558\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a system for hearbeat detection using microwave Doppler technique. Using a vector network analyzer, a microwave system is tested for the detection of the heartbeat signal at a distance of 1 feet from a person. The proposed system shows the ability of detecting the heartbeat signals with the possibility of tuning the radiated power. Measurements are performed at 10dbm, 0dbm, -10dbm, -15dbm and -25dbm. Based on measurements perform for respiration and heart beatings, a signal representing the cardiopulmonary activity is presented. The heartbeat rate and heart rate are extracted from the signal using wavelet and classic filters.\",\"PeriodicalId\":364834,\"journal\":{\"name\":\"2014 International Symposium on Technology Management and Emerging Technologies\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-05-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 International Symposium on Technology Management and Emerging Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISTMET.2014.6936558\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Symposium on Technology Management and Emerging Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISTMET.2014.6936558","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
An analysis of vital sign using microwave Doppler technique
This paper presents a system for hearbeat detection using microwave Doppler technique. Using a vector network analyzer, a microwave system is tested for the detection of the heartbeat signal at a distance of 1 feet from a person. The proposed system shows the ability of detecting the heartbeat signals with the possibility of tuning the radiated power. Measurements are performed at 10dbm, 0dbm, -10dbm, -15dbm and -25dbm. Based on measurements perform for respiration and heart beatings, a signal representing the cardiopulmonary activity is presented. The heartbeat rate and heart rate are extracted from the signal using wavelet and classic filters.