{"title":"无电流环PI控制器的三相有源前端PWM整流器性能分析","authors":"A. Mitra, P. Bhowmik, S. Chowdhuri","doi":"10.1109/CIEC.2016.7513752","DOIUrl":null,"url":null,"abstract":"This work investigates the performance of an Active Front-End (AFE) Rectifier with direct and quadrature axis current control method. Most of the research works describe that the controller for an AFE Rectifier requires three Proportional-Integral (PI) controllers to regulate DC voltage, d-axis and q-axis current. Normally, the outer loop for DC voltage control requires high gain value to stabilize the DC voltage and the inner loop for current control requires low gain values to regulate the current. In this proposed work, due to lower gain of the inner current loop, the PI controllers for that specific loop has been omitted to deal with the easy control of the controller.","PeriodicalId":443343,"journal":{"name":"2016 2nd International Conference on Control, Instrumentation, Energy & Communication (CIEC)","volume":"39 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Performance analysis of a three-phase Active Front-End PWM Rectifier without current loop PI controller\",\"authors\":\"A. Mitra, P. Bhowmik, S. Chowdhuri\",\"doi\":\"10.1109/CIEC.2016.7513752\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This work investigates the performance of an Active Front-End (AFE) Rectifier with direct and quadrature axis current control method. Most of the research works describe that the controller for an AFE Rectifier requires three Proportional-Integral (PI) controllers to regulate DC voltage, d-axis and q-axis current. Normally, the outer loop for DC voltage control requires high gain value to stabilize the DC voltage and the inner loop for current control requires low gain values to regulate the current. In this proposed work, due to lower gain of the inner current loop, the PI controllers for that specific loop has been omitted to deal with the easy control of the controller.\",\"PeriodicalId\":443343,\"journal\":{\"name\":\"2016 2nd International Conference on Control, Instrumentation, Energy & Communication (CIEC)\",\"volume\":\"39 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 2nd International Conference on Control, Instrumentation, Energy & Communication (CIEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIEC.2016.7513752\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 2nd International Conference on Control, Instrumentation, Energy & Communication (CIEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIEC.2016.7513752","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文研究了采用直接和正交轴电流控制方法的有源前端(AFE)整流器的性能。大多数研究工作描述了AFE整流器的控制器需要三个比例积分(PI)控制器来调节直流电压,d轴和q轴电流。通常,用于直流电压控制的外环需要高增益值来稳定直流电压,而用于电流控制的内环需要低增益值来调节电流。在本工作中,由于内电流环的增益较低,因此省略了该特定环路的PI控制器,以处理控制器的易于控制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Performance analysis of a three-phase Active Front-End PWM Rectifier without current loop PI controller
This work investigates the performance of an Active Front-End (AFE) Rectifier with direct and quadrature axis current control method. Most of the research works describe that the controller for an AFE Rectifier requires three Proportional-Integral (PI) controllers to regulate DC voltage, d-axis and q-axis current. Normally, the outer loop for DC voltage control requires high gain value to stabilize the DC voltage and the inner loop for current control requires low gain values to regulate the current. In this proposed work, due to lower gain of the inner current loop, the PI controllers for that specific loop has been omitted to deal with the easy control of the controller.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信