T. Morishige, T. Mihaya, T. Miyazai, T. Yoshida, M. Matsuo, K. Enpuku
{"title":"利用冷却铜/高温超导拾取线圈的磁性纳米粒子成像","authors":"T. Morishige, T. Mihaya, T. Miyazai, T. Yoshida, M. Matsuo, K. Enpuku","doi":"10.1109/ISEC.2013.6604312","DOIUrl":null,"url":null,"abstract":"We developed a highly sensitive measurement system of AC magnetic fields for magnetic nanoparticle imaging (MPI). First, we developed a detection system using pickup coils made of cooled Cu wire and HTS tape. The pickup coils were connected to a resonant capacitor in order to enhance the signal voltage generated in the pickup coils. The magnetic field noise at the resonant frequency was as low as 90 fT/Hz1/2 and 13 fT/Hz1/2 for the Cu and HTS coils, respectively. Next, we demonstrated the detection of nanoparticles using third-harmonic signal generated by the nonlinear magnetization of nanoparticles. An excitation field having a frequency of 1 kHz and an amplitude of 1.6 mT was applied to the magnetic particles and the third harmonic signal at 3 kHz was detected in order to reduce the interference from the excitation field. We demonstrated the detection of 0.1 mg of magnetic nanoparticles. We obtained a clear contour map of the magnetic field from the particles, and could detect the particles located as far as 100 mm under the pickup coil.","PeriodicalId":233581,"journal":{"name":"2013 IEEE 14th International Superconductive Electronics Conference (ISEC)","volume":"50 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-07-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Magnetic nanoparticle imaging using cooled-Cu/HTS-superconductor pickup coils\",\"authors\":\"T. Morishige, T. Mihaya, T. Miyazai, T. Yoshida, M. Matsuo, K. Enpuku\",\"doi\":\"10.1109/ISEC.2013.6604312\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We developed a highly sensitive measurement system of AC magnetic fields for magnetic nanoparticle imaging (MPI). First, we developed a detection system using pickup coils made of cooled Cu wire and HTS tape. The pickup coils were connected to a resonant capacitor in order to enhance the signal voltage generated in the pickup coils. The magnetic field noise at the resonant frequency was as low as 90 fT/Hz1/2 and 13 fT/Hz1/2 for the Cu and HTS coils, respectively. Next, we demonstrated the detection of nanoparticles using third-harmonic signal generated by the nonlinear magnetization of nanoparticles. An excitation field having a frequency of 1 kHz and an amplitude of 1.6 mT was applied to the magnetic particles and the third harmonic signal at 3 kHz was detected in order to reduce the interference from the excitation field. We demonstrated the detection of 0.1 mg of magnetic nanoparticles. We obtained a clear contour map of the magnetic field from the particles, and could detect the particles located as far as 100 mm under the pickup coil.\",\"PeriodicalId\":233581,\"journal\":{\"name\":\"2013 IEEE 14th International Superconductive Electronics Conference (ISEC)\",\"volume\":\"50 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-07-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE 14th International Superconductive Electronics Conference (ISEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISEC.2013.6604312\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE 14th International Superconductive Electronics Conference (ISEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEC.2013.6604312","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Magnetic nanoparticle imaging using cooled-Cu/HTS-superconductor pickup coils
We developed a highly sensitive measurement system of AC magnetic fields for magnetic nanoparticle imaging (MPI). First, we developed a detection system using pickup coils made of cooled Cu wire and HTS tape. The pickup coils were connected to a resonant capacitor in order to enhance the signal voltage generated in the pickup coils. The magnetic field noise at the resonant frequency was as low as 90 fT/Hz1/2 and 13 fT/Hz1/2 for the Cu and HTS coils, respectively. Next, we demonstrated the detection of nanoparticles using third-harmonic signal generated by the nonlinear magnetization of nanoparticles. An excitation field having a frequency of 1 kHz and an amplitude of 1.6 mT was applied to the magnetic particles and the third harmonic signal at 3 kHz was detected in order to reduce the interference from the excitation field. We demonstrated the detection of 0.1 mg of magnetic nanoparticles. We obtained a clear contour map of the magnetic field from the particles, and could detect the particles located as far as 100 mm under the pickup coil.