{"title":"一种基于智能手机的实时非接触式脉搏率检测器","authors":"Min-che Li, Yuan-Hsiang Lin","doi":"10.1109/ISNE.2015.7132025","DOIUrl":null,"url":null,"abstract":"A non-contact method to extract human cardiac pulse rate non-invasively is more affordable and convenient compared with conventional method using contact electrode. This paper developed a video method to extract pulse rate based on smartphone. Using the front camera of smartphone to capture image frame data of human face region, defined as ROI (region of interest) for extracting PPG signal. And to suppress motion artifacts that lead to calculation error while monitoring, we need to make ROI coordinates on human face stable and accurate. So we use face detection to get the location of human face initially, then using optical flow feature tracking keep tracking the feature points in ROI. Furthermore, Kalman filter is used to stable coordinates of ROI and enhance the waveform of PPG signal. The accuracy of pulse rate detection was evaluated by compared with FDA approved vital signs monitor.","PeriodicalId":152001,"journal":{"name":"2015 International Symposium on Next-Generation Electronics (ISNE)","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-05-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":"{\"title\":\"A real-time non-contact pulse rate detector based on smartphone\",\"authors\":\"Min-che Li, Yuan-Hsiang Lin\",\"doi\":\"10.1109/ISNE.2015.7132025\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A non-contact method to extract human cardiac pulse rate non-invasively is more affordable and convenient compared with conventional method using contact electrode. This paper developed a video method to extract pulse rate based on smartphone. Using the front camera of smartphone to capture image frame data of human face region, defined as ROI (region of interest) for extracting PPG signal. And to suppress motion artifacts that lead to calculation error while monitoring, we need to make ROI coordinates on human face stable and accurate. So we use face detection to get the location of human face initially, then using optical flow feature tracking keep tracking the feature points in ROI. Furthermore, Kalman filter is used to stable coordinates of ROI and enhance the waveform of PPG signal. The accuracy of pulse rate detection was evaluated by compared with FDA approved vital signs monitor.\",\"PeriodicalId\":152001,\"journal\":{\"name\":\"2015 International Symposium on Next-Generation Electronics (ISNE)\",\"volume\":\"11 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-05-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Symposium on Next-Generation Electronics (ISNE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISNE.2015.7132025\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Symposium on Next-Generation Electronics (ISNE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISNE.2015.7132025","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A real-time non-contact pulse rate detector based on smartphone
A non-contact method to extract human cardiac pulse rate non-invasively is more affordable and convenient compared with conventional method using contact electrode. This paper developed a video method to extract pulse rate based on smartphone. Using the front camera of smartphone to capture image frame data of human face region, defined as ROI (region of interest) for extracting PPG signal. And to suppress motion artifacts that lead to calculation error while monitoring, we need to make ROI coordinates on human face stable and accurate. So we use face detection to get the location of human face initially, then using optical flow feature tracking keep tracking the feature points in ROI. Furthermore, Kalman filter is used to stable coordinates of ROI and enhance the waveform of PPG signal. The accuracy of pulse rate detection was evaluated by compared with FDA approved vital signs monitor.