一种基于智能手机的实时非接触式脉搏率检测器

Min-che Li, Yuan-Hsiang Lin
{"title":"一种基于智能手机的实时非接触式脉搏率检测器","authors":"Min-che Li, Yuan-Hsiang Lin","doi":"10.1109/ISNE.2015.7132025","DOIUrl":null,"url":null,"abstract":"A non-contact method to extract human cardiac pulse rate non-invasively is more affordable and convenient compared with conventional method using contact electrode. This paper developed a video method to extract pulse rate based on smartphone. Using the front camera of smartphone to capture image frame data of human face region, defined as ROI (region of interest) for extracting PPG signal. And to suppress motion artifacts that lead to calculation error while monitoring, we need to make ROI coordinates on human face stable and accurate. So we use face detection to get the location of human face initially, then using optical flow feature tracking keep tracking the feature points in ROI. Furthermore, Kalman filter is used to stable coordinates of ROI and enhance the waveform of PPG signal. The accuracy of pulse rate detection was evaluated by compared with FDA approved vital signs monitor.","PeriodicalId":152001,"journal":{"name":"2015 International Symposium on Next-Generation Electronics (ISNE)","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-05-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":"{\"title\":\"A real-time non-contact pulse rate detector based on smartphone\",\"authors\":\"Min-che Li, Yuan-Hsiang Lin\",\"doi\":\"10.1109/ISNE.2015.7132025\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A non-contact method to extract human cardiac pulse rate non-invasively is more affordable and convenient compared with conventional method using contact electrode. This paper developed a video method to extract pulse rate based on smartphone. Using the front camera of smartphone to capture image frame data of human face region, defined as ROI (region of interest) for extracting PPG signal. And to suppress motion artifacts that lead to calculation error while monitoring, we need to make ROI coordinates on human face stable and accurate. So we use face detection to get the location of human face initially, then using optical flow feature tracking keep tracking the feature points in ROI. Furthermore, Kalman filter is used to stable coordinates of ROI and enhance the waveform of PPG signal. The accuracy of pulse rate detection was evaluated by compared with FDA approved vital signs monitor.\",\"PeriodicalId\":152001,\"journal\":{\"name\":\"2015 International Symposium on Next-Generation Electronics (ISNE)\",\"volume\":\"11 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-05-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Symposium on Next-Generation Electronics (ISNE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISNE.2015.7132025\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Symposium on Next-Generation Electronics (ISNE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISNE.2015.7132025","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

摘要

与传统的接触电极法相比,一种非接触式无创提取人体脉搏率的方法更经济、更方便。本文开发了一种基于智能手机的视频脉搏率提取方法。利用智能手机前置摄像头采集人脸区域的图像帧数据,定义为感兴趣区域(ROI),提取PPG信号。为了抑制在监控过程中产生的运动伪影导致的计算误差,需要使人脸上的ROI坐标稳定准确。因此我们首先利用人脸检测得到人脸的位置,然后利用光流特征跟踪对ROI中的特征点进行持续跟踪。利用卡尔曼滤波稳定感兴趣区域的坐标,增强PPG信号的波形。通过与FDA批准的生命体征监测仪进行比较,评价脉搏率检测的准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A real-time non-contact pulse rate detector based on smartphone
A non-contact method to extract human cardiac pulse rate non-invasively is more affordable and convenient compared with conventional method using contact electrode. This paper developed a video method to extract pulse rate based on smartphone. Using the front camera of smartphone to capture image frame data of human face region, defined as ROI (region of interest) for extracting PPG signal. And to suppress motion artifacts that lead to calculation error while monitoring, we need to make ROI coordinates on human face stable and accurate. So we use face detection to get the location of human face initially, then using optical flow feature tracking keep tracking the feature points in ROI. Furthermore, Kalman filter is used to stable coordinates of ROI and enhance the waveform of PPG signal. The accuracy of pulse rate detection was evaluated by compared with FDA approved vital signs monitor.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信