{"title":"胰岛素:时间、剂量可控电子胰岛素笔设计","authors":"M. Sezdi, A. Bilen","doi":"10.1109/TIPTEKNO.2016.7863126","DOIUrl":null,"url":null,"abstract":"In this study, an electronic insulin pen was designed for diabetic patients dependent on insulin use in order to prevent wrong timing and wrong dosage caused from old age, vision or mental illness. The insulin pen that can be used electronically for routine dose injections, and that is called as bilensülin, was designed to be able to used manually in the emergency. It is aimed that the patient can set the dose easily by using the fairly simple menu of the device. Additionally, the device was not designed as disposable, the device was designed as reusable by changing the insulin tube. Because the tube chamber was designed to be suitable for all types of insulin, it can be used by changing tube without using different pen. Dose accuracy was adjusted with low error by performing insulin dose measurements on a sensitive balance. Patent was attempted for the designed electronic insulin pen, and the studies on the device are continuing.","PeriodicalId":431660,"journal":{"name":"2016 Medical Technologies National Congress (TIPTEKNO)","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Bilensulin: Time and dose controlled electronic insulin pen design\",\"authors\":\"M. Sezdi, A. Bilen\",\"doi\":\"10.1109/TIPTEKNO.2016.7863126\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study, an electronic insulin pen was designed for diabetic patients dependent on insulin use in order to prevent wrong timing and wrong dosage caused from old age, vision or mental illness. The insulin pen that can be used electronically for routine dose injections, and that is called as bilensülin, was designed to be able to used manually in the emergency. It is aimed that the patient can set the dose easily by using the fairly simple menu of the device. Additionally, the device was not designed as disposable, the device was designed as reusable by changing the insulin tube. Because the tube chamber was designed to be suitable for all types of insulin, it can be used by changing tube without using different pen. Dose accuracy was adjusted with low error by performing insulin dose measurements on a sensitive balance. Patent was attempted for the designed electronic insulin pen, and the studies on the device are continuing.\",\"PeriodicalId\":431660,\"journal\":{\"name\":\"2016 Medical Technologies National Congress (TIPTEKNO)\",\"volume\":\"25 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 Medical Technologies National Congress (TIPTEKNO)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TIPTEKNO.2016.7863126\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 Medical Technologies National Congress (TIPTEKNO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TIPTEKNO.2016.7863126","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本研究针对依赖胰岛素使用的糖尿病患者设计了一款电子胰岛素笔,以防止因老年、视力或精神疾病导致的错误时间和错误剂量。这种名为bilens lin的胰岛素笔可以通过电子方式进行常规剂量注射,它的设计初衷是在紧急情况下可以手动使用。其目的是患者可以通过使用设备相当简单的菜单轻松设置剂量。此外,该装置不是一次性设计的,而是通过更换胰岛素管可重复使用的。由于管腔设计适用于所有类型的胰岛素,因此可以通过更换管而无需使用不同的笔来使用。通过在灵敏天平上进行胰岛素剂量测量,以低误差调整剂量准确性。所设计的电子胰岛素笔正在申请专利,并继续进行研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Bilensulin: Time and dose controlled electronic insulin pen design
In this study, an electronic insulin pen was designed for diabetic patients dependent on insulin use in order to prevent wrong timing and wrong dosage caused from old age, vision or mental illness. The insulin pen that can be used electronically for routine dose injections, and that is called as bilensülin, was designed to be able to used manually in the emergency. It is aimed that the patient can set the dose easily by using the fairly simple menu of the device. Additionally, the device was not designed as disposable, the device was designed as reusable by changing the insulin tube. Because the tube chamber was designed to be suitable for all types of insulin, it can be used by changing tube without using different pen. Dose accuracy was adjusted with low error by performing insulin dose measurements on a sensitive balance. Patent was attempted for the designed electronic insulin pen, and the studies on the device are continuing.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信