改进风力机驱动DFIG动态响应的新方法

Mostafa Eidiani, Natan Asghari Shahdehi, H. Zeynal
{"title":"改进风力机驱动DFIG动态响应的新方法","authors":"Mostafa Eidiani, Natan Asghari Shahdehi, H. Zeynal","doi":"10.1109/SCORED.2011.6148770","DOIUrl":null,"url":null,"abstract":"The frequency converter is the most sensitive part in the variable-speed wind turbine generator system equipped with a double-fed induction generator (DFIG). The frequency converter is normally controlled by a set of PI controllers. In order to improve the response of DFIG when subjected to system disturbances, the best way is to tune the PI controllers of the frequency converter. Due to the high complexity of the system, the tuning of these PI controllers is very difficult. In this paper an approach is offered to improve the response of DFIG when subjected to system disturbances using Hybrid Particle Swarm Optimization and Genetic Algorithm (PSO-GA). In this case, tuning all PI controllers' parameters is considered. The results show that the proposed algorithm is well suited in terms of accuracy and quick response.","PeriodicalId":383828,"journal":{"name":"2011 IEEE Student Conference on Research and Development","volume":"796 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Improving dynamic response of wind turbine driven DFIG with novel approach\",\"authors\":\"Mostafa Eidiani, Natan Asghari Shahdehi, H. Zeynal\",\"doi\":\"10.1109/SCORED.2011.6148770\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The frequency converter is the most sensitive part in the variable-speed wind turbine generator system equipped with a double-fed induction generator (DFIG). The frequency converter is normally controlled by a set of PI controllers. In order to improve the response of DFIG when subjected to system disturbances, the best way is to tune the PI controllers of the frequency converter. Due to the high complexity of the system, the tuning of these PI controllers is very difficult. In this paper an approach is offered to improve the response of DFIG when subjected to system disturbances using Hybrid Particle Swarm Optimization and Genetic Algorithm (PSO-GA). In this case, tuning all PI controllers' parameters is considered. The results show that the proposed algorithm is well suited in terms of accuracy and quick response.\",\"PeriodicalId\":383828,\"journal\":{\"name\":\"2011 IEEE Student Conference on Research and Development\",\"volume\":\"796 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 IEEE Student Conference on Research and Development\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SCORED.2011.6148770\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE Student Conference on Research and Development","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SCORED.2011.6148770","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

在采用双馈感应发电机的变速风力发电系统中,变频器是最敏感的部件。变频器通常由一组PI控制器控制。为了改善DFIG在系统扰动下的响应,最好的方法是对变频器的PI控制器进行调优。由于系统的高度复杂性,这些PI控制器的整定非常困难。本文提出了一种利用混合粒子群优化和遗传算法(PSO-GA)改善DFIG在系统扰动下的响应的方法。在这种情况下,要考虑调优所有PI控制器的参数。结果表明,该算法具有较好的精度和快速响应性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Improving dynamic response of wind turbine driven DFIG with novel approach
The frequency converter is the most sensitive part in the variable-speed wind turbine generator system equipped with a double-fed induction generator (DFIG). The frequency converter is normally controlled by a set of PI controllers. In order to improve the response of DFIG when subjected to system disturbances, the best way is to tune the PI controllers of the frequency converter. Due to the high complexity of the system, the tuning of these PI controllers is very difficult. In this paper an approach is offered to improve the response of DFIG when subjected to system disturbances using Hybrid Particle Swarm Optimization and Genetic Algorithm (PSO-GA). In this case, tuning all PI controllers' parameters is considered. The results show that the proposed algorithm is well suited in terms of accuracy and quick response.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信