非接触式眼压测量中角膜变形的在线测量

T. Krijger, M. Kaneko
{"title":"非接触式眼压测量中角膜变形的在线测量","authors":"T. Krijger, M. Kaneko","doi":"10.1109/ICSENS.2011.6127401","DOIUrl":null,"url":null,"abstract":"A novel method to achieve online measurements of cornea deformation during non-contact tonometry by use of an online camera system is presented. Kaneko et al. have shown that non-contact tonometry as a method of identifying the intraocular pressure can produce biased results due to differences in structural eye stiffness between individuals. By including deformation measurements of the cornea, results can be greatly improved. An experimental set-up was created implementing an online camera system to allow for real time measurement of cornea deformation. Initial results using the improved setup decreased analysis time from the initial 30 minutes using the offline system to less than one minute using the online system.","PeriodicalId":201386,"journal":{"name":"2011 IEEE SENSORS Proceedings","volume":"32 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Online measurement of cornea deformation during non-contact tonometry\",\"authors\":\"T. Krijger, M. Kaneko\",\"doi\":\"10.1109/ICSENS.2011.6127401\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A novel method to achieve online measurements of cornea deformation during non-contact tonometry by use of an online camera system is presented. Kaneko et al. have shown that non-contact tonometry as a method of identifying the intraocular pressure can produce biased results due to differences in structural eye stiffness between individuals. By including deformation measurements of the cornea, results can be greatly improved. An experimental set-up was created implementing an online camera system to allow for real time measurement of cornea deformation. Initial results using the improved setup decreased analysis time from the initial 30 minutes using the offline system to less than one minute using the online system.\",\"PeriodicalId\":201386,\"journal\":{\"name\":\"2011 IEEE SENSORS Proceedings\",\"volume\":\"32 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 IEEE SENSORS Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSENS.2011.6127401\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE SENSORS Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENS.2011.6127401","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

提出了一种利用在线摄像系统实现非接触式眼压测量过程中角膜变形在线测量的新方法。Kaneko等人的研究表明,非接触式眼压测量作为一种识别眼压的方法,由于个体之间眼睛结构刚度的差异,可能会产生有偏差的结果。通过包括角膜变形测量,结果可以大大改善。建立了一个实验装置,实现了一个在线摄像系统,允许实时测量角膜变形。使用改进设置的初步结果将分析时间从最初使用离线系统的30分钟减少到使用在线系统的不到1分钟。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Online measurement of cornea deformation during non-contact tonometry
A novel method to achieve online measurements of cornea deformation during non-contact tonometry by use of an online camera system is presented. Kaneko et al. have shown that non-contact tonometry as a method of identifying the intraocular pressure can produce biased results due to differences in structural eye stiffness between individuals. By including deformation measurements of the cornea, results can be greatly improved. An experimental set-up was created implementing an online camera system to allow for real time measurement of cornea deformation. Initial results using the improved setup decreased analysis time from the initial 30 minutes using the offline system to less than one minute using the online system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信