用于430MHz无线消化监测系统的小型化贴片天线

Tlili Malika, K. Abdennaceur, Abdaoui Rahma, Amiel Frederic
{"title":"用于430MHz无线消化监测系统的小型化贴片天线","authors":"Tlili Malika, K. Abdennaceur, Abdaoui Rahma, Amiel Frederic","doi":"10.1109/BIOMS.2014.6951536","DOIUrl":null,"url":null,"abstract":"Biomedical and health applications are representing nowadays a very attractive area for electronics devices. The state of the art shows a multitude of solutions based on in body sensors devices to measure and survey human physiological parameters enabling a distance medical monitoring systems and higher out-of-hospital care services for patients. These emergent systems have a lot of challenges related to their power consumption, size and complexity. In this article, we focus on one of the technological locks of the electronic gastric pill, which is the antenna. A miniaturized patch antenna a key element of the receiving system is presented. The antenna size and performances are very important to consider as it have to be integrated on a jacket in order to collect the transmitted information from an electronic gastric pill to trace cartography of the collected data. Different miniaturization techniques of patch antennas are combined with the use high dielectric constant substrate in order to reach a tradeoff between the antenna performances and the size. The designed antenna resonates in the desired ISM frequency band (430 MHz) and was simulated and optimized with the presence of a model of the human body for a more realistic use case. The antenna size reduction achieves 81.56% with good performances in terms of gain (-29.4dB).","PeriodicalId":175781,"journal":{"name":"2014 IEEE Workshop on Biometric Measurements and Systems for Security and Medical Applications (BIOMS) Proceedings","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Miniaturized on-body patch antenna for 430MHz wireless digestive monitoring system\",\"authors\":\"Tlili Malika, K. Abdennaceur, Abdaoui Rahma, Amiel Frederic\",\"doi\":\"10.1109/BIOMS.2014.6951536\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Biomedical and health applications are representing nowadays a very attractive area for electronics devices. The state of the art shows a multitude of solutions based on in body sensors devices to measure and survey human physiological parameters enabling a distance medical monitoring systems and higher out-of-hospital care services for patients. These emergent systems have a lot of challenges related to their power consumption, size and complexity. In this article, we focus on one of the technological locks of the electronic gastric pill, which is the antenna. A miniaturized patch antenna a key element of the receiving system is presented. The antenna size and performances are very important to consider as it have to be integrated on a jacket in order to collect the transmitted information from an electronic gastric pill to trace cartography of the collected data. Different miniaturization techniques of patch antennas are combined with the use high dielectric constant substrate in order to reach a tradeoff between the antenna performances and the size. The designed antenna resonates in the desired ISM frequency band (430 MHz) and was simulated and optimized with the presence of a model of the human body for a more realistic use case. The antenna size reduction achieves 81.56% with good performances in terms of gain (-29.4dB).\",\"PeriodicalId\":175781,\"journal\":{\"name\":\"2014 IEEE Workshop on Biometric Measurements and Systems for Security and Medical Applications (BIOMS) Proceedings\",\"volume\":\"18 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-11-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE Workshop on Biometric Measurements and Systems for Security and Medical Applications (BIOMS) Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BIOMS.2014.6951536\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE Workshop on Biometric Measurements and Systems for Security and Medical Applications (BIOMS) Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIOMS.2014.6951536","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

生物医学和健康应用是当今电子设备的一个非常有吸引力的领域。最先进的技术显示了许多基于体内传感器设备的解决方案,以测量和调查人体生理参数,从而实现远程医疗监控系统和更高的院外护理服务。这些紧急系统在功耗、大小和复杂性方面面临许多挑战。本文重点介绍了电子胃丸的技术锁之一,即天线。介绍了一种小型贴片天线,它是接收系统的关键元件。天线的尺寸和性能是非常重要的考虑因素,因为它必须集成在夹克上,以便收集来自电子胃丸的传输信息,以跟踪收集到的数据的制图。不同的贴片天线小型化技术与使用高介电常数衬底相结合,以达到天线性能与尺寸之间的平衡。设计的天线在期望的ISM频段(430 MHz)内谐振,并在人体模型的存在下进行了仿真和优化,以实现更现实的用例。天线尺寸减小81.56%,增益(-29.4dB)方面表现良好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Miniaturized on-body patch antenna for 430MHz wireless digestive monitoring system
Biomedical and health applications are representing nowadays a very attractive area for electronics devices. The state of the art shows a multitude of solutions based on in body sensors devices to measure and survey human physiological parameters enabling a distance medical monitoring systems and higher out-of-hospital care services for patients. These emergent systems have a lot of challenges related to their power consumption, size and complexity. In this article, we focus on one of the technological locks of the electronic gastric pill, which is the antenna. A miniaturized patch antenna a key element of the receiving system is presented. The antenna size and performances are very important to consider as it have to be integrated on a jacket in order to collect the transmitted information from an electronic gastric pill to trace cartography of the collected data. Different miniaturization techniques of patch antennas are combined with the use high dielectric constant substrate in order to reach a tradeoff between the antenna performances and the size. The designed antenna resonates in the desired ISM frequency band (430 MHz) and was simulated and optimized with the presence of a model of the human body for a more realistic use case. The antenna size reduction achieves 81.56% with good performances in terms of gain (-29.4dB).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信