光学传感器在电力变压器高频过电压测量中的应用

D. Chatrefou, M. Pristchepa, D. Uhde
{"title":"光学传感器在电力变压器高频过电压测量中的应用","authors":"D. Chatrefou, M. Pristchepa, D. Uhde","doi":"10.1109/PESW.2000.847707","DOIUrl":null,"url":null,"abstract":"For power utilities and the manufacturers of power transformers, the knowledge of very fast transient overvoltages (VFTO) in the network is of great interest. Indeed, the VFTOs contain frequencies far above those arising in conventional open-air substations and may, for example, be associated with faults or resonance in GIS insulation or in the insulation of other equipment connected to it such as the transformer. The knowledge of the generated VFTOs is strategic to avoid damage on the insulation system of the connected equipment. Until today no device really exists industrially capable of measuring such high frequencies with a suitable bandwidth. Alstom has developed a special \"on-line\" sensor, based on the optical sensor technology. A fraction of the high voltage is given by a geometrical capacitive divider near the base of the high voltage bushing. This fraction of voltage is applied to a Pockels cell specially studied to measure high frequencies. The use of optical transmission to the electronics provides good protection against electromagnetic disturbances and guarantees correct representation of the VFTO. The measurement allows validations of mathematical simulations of the generated VFTOs. This information is now available in the design stage of the substation.","PeriodicalId":286352,"journal":{"name":"2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077)","volume":"206 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-01-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Application of optical sensors for measurement of high frequency overvoltages in power transformers\",\"authors\":\"D. Chatrefou, M. Pristchepa, D. Uhde\",\"doi\":\"10.1109/PESW.2000.847707\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"For power utilities and the manufacturers of power transformers, the knowledge of very fast transient overvoltages (VFTO) in the network is of great interest. Indeed, the VFTOs contain frequencies far above those arising in conventional open-air substations and may, for example, be associated with faults or resonance in GIS insulation or in the insulation of other equipment connected to it such as the transformer. The knowledge of the generated VFTOs is strategic to avoid damage on the insulation system of the connected equipment. Until today no device really exists industrially capable of measuring such high frequencies with a suitable bandwidth. Alstom has developed a special \\\"on-line\\\" sensor, based on the optical sensor technology. A fraction of the high voltage is given by a geometrical capacitive divider near the base of the high voltage bushing. This fraction of voltage is applied to a Pockels cell specially studied to measure high frequencies. The use of optical transmission to the electronics provides good protection against electromagnetic disturbances and guarantees correct representation of the VFTO. The measurement allows validations of mathematical simulations of the generated VFTOs. This information is now available in the design stage of the substation.\",\"PeriodicalId\":286352,\"journal\":{\"name\":\"2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077)\",\"volume\":\"206 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-01-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PESW.2000.847707\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESW.2000.847707","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

对于电力公司和电力变压器制造商来说,了解电网中的快速暂态过电压(VFTO)是非常重要的。事实上,vfto包含的频率远远高于传统露天变电站产生的频率,例如,可能与GIS绝缘或与之相连的其他设备(如变压器)的绝缘中的故障或共振有关。了解产生的vfto是避免对连接设备的绝缘系统造成损坏的策略。直到今天,工业上还没有设备能够在合适的带宽下测量如此高的频率。阿尔斯通在光学传感器技术的基础上开发了一种特殊的“在线”传感器。高压的一小部分是由高压套管底部附近的几何电容分压器提供的。这部分电压被施加到专门用于测量高频的波克尔斯电池上。使用光传输到电子器件提供了良好的电磁干扰保护,并保证了VFTO的正确表示。该测量允许对生成的vfto进行数学模拟验证。这些信息现在可以在变电站的设计阶段获得。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Application of optical sensors for measurement of high frequency overvoltages in power transformers
For power utilities and the manufacturers of power transformers, the knowledge of very fast transient overvoltages (VFTO) in the network is of great interest. Indeed, the VFTOs contain frequencies far above those arising in conventional open-air substations and may, for example, be associated with faults or resonance in GIS insulation or in the insulation of other equipment connected to it such as the transformer. The knowledge of the generated VFTOs is strategic to avoid damage on the insulation system of the connected equipment. Until today no device really exists industrially capable of measuring such high frequencies with a suitable bandwidth. Alstom has developed a special "on-line" sensor, based on the optical sensor technology. A fraction of the high voltage is given by a geometrical capacitive divider near the base of the high voltage bushing. This fraction of voltage is applied to a Pockels cell specially studied to measure high frequencies. The use of optical transmission to the electronics provides good protection against electromagnetic disturbances and guarantees correct representation of the VFTO. The measurement allows validations of mathematical simulations of the generated VFTOs. This information is now available in the design stage of the substation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信