Anwar H. Al-Assaf, O. Alrebei, Abdulkarem I. Amhamed, Mahmoud Hayajnh, Ward Fawaz, Ahmad S. Al-Tawaha
{"title":"PID功率控制器到蓄水池液位高度设定值,用于无人值守监测","authors":"Anwar H. Al-Assaf, O. Alrebei, Abdulkarem I. Amhamed, Mahmoud Hayajnh, Ward Fawaz, Ahmad S. Al-Tawaha","doi":"10.37745/ijeees.13/vol10n1pp113","DOIUrl":null,"url":null,"abstract":"This paper provides a novel approach of a power control system of a fluid tank pump to reach a specific setpoint of fluid level height. The system enables users to fill a tank to any desired height within a chosen time interval. The system is equipped with a timer that allows the user to fill the tank to the desired level within the desired time. The system is based on utilizing a Proportional Integral and Derivative (PID) controller to adjust the pump's power to satisfy the us-er-defined setups (time and fluid level height). This approach has the potential to be applied for domestic purposes for unattended human monitoring. This approach has been demonstrated using LabVIEW coding to apply the fluid and hydrodynamic design and control principles. The results have illustrated the code's capability to achieve the desired tank fluid level height for a variable range of fluid level height setpoints and time intervals","PeriodicalId":167829,"journal":{"name":"International Journal of Electrical and Electronics Engineering Studies","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"PID Power Controller to a Setpoint of Fluid Level Height in a Reservoir for Unattended Human Monitoring\",\"authors\":\"Anwar H. Al-Assaf, O. Alrebei, Abdulkarem I. Amhamed, Mahmoud Hayajnh, Ward Fawaz, Ahmad S. Al-Tawaha\",\"doi\":\"10.37745/ijeees.13/vol10n1pp113\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper provides a novel approach of a power control system of a fluid tank pump to reach a specific setpoint of fluid level height. The system enables users to fill a tank to any desired height within a chosen time interval. The system is equipped with a timer that allows the user to fill the tank to the desired level within the desired time. The system is based on utilizing a Proportional Integral and Derivative (PID) controller to adjust the pump's power to satisfy the us-er-defined setups (time and fluid level height). This approach has the potential to be applied for domestic purposes for unattended human monitoring. This approach has been demonstrated using LabVIEW coding to apply the fluid and hydrodynamic design and control principles. The results have illustrated the code's capability to achieve the desired tank fluid level height for a variable range of fluid level height setpoints and time intervals\",\"PeriodicalId\":167829,\"journal\":{\"name\":\"International Journal of Electrical and Electronics Engineering Studies\",\"volume\":\"10 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Electrical and Electronics Engineering Studies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.37745/ijeees.13/vol10n1pp113\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Electrical and Electronics Engineering Studies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.37745/ijeees.13/vol10n1pp113","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
PID Power Controller to a Setpoint of Fluid Level Height in a Reservoir for Unattended Human Monitoring
This paper provides a novel approach of a power control system of a fluid tank pump to reach a specific setpoint of fluid level height. The system enables users to fill a tank to any desired height within a chosen time interval. The system is equipped with a timer that allows the user to fill the tank to the desired level within the desired time. The system is based on utilizing a Proportional Integral and Derivative (PID) controller to adjust the pump's power to satisfy the us-er-defined setups (time and fluid level height). This approach has the potential to be applied for domestic purposes for unattended human monitoring. This approach has been demonstrated using LabVIEW coding to apply the fluid and hydrodynamic design and control principles. The results have illustrated the code's capability to achieve the desired tank fluid level height for a variable range of fluid level height setpoints and time intervals