{"title":"基于无差拍算法的三相电流源有源滤波器电流控制新方案","authors":"K. Nishida, Y. Konishi, M. Nakaoka","doi":"10.1109/ISIE.2001.931571","DOIUrl":null,"url":null,"abstract":"For an active power filter (APF), the three-phase current source PWM converter is not always used in place of three-phase voltage source PWM converter with voltage regulated DC capacitor. This is due to the difficulty of current control implementation for current source PWM converters. In this paper, an effective method to apply a three-phase current-source PWM converter with a deadbeat controller to an APF is presented. In this APF, the compensation of current harmonics is attained by setting the control purpose, compensating the instantaneous reactive current component in the load current and reducing the ripple in the instantaneous effective current component. In a three-phase current source PWM converter, the time-optimal response of the utility AC grid side input current is two-dimensional finite time settling response, in which two sampling periods are required for a settling time. To cancel this delay, and one more delays caused by the DSP control strategy, a reference value three sampling periods ahead has to be predicted. For this prediction, the reference value detected previously can be useful, because the waveform of harmonic current is periodical in many cases. Finally, it is proven, from an experimental point of view, that the compensating ability of this APF is very high.","PeriodicalId":124749,"journal":{"name":"ISIE 2001. 2001 IEEE International Symposium on Industrial Electronics Proceedings (Cat. No.01TH8570)","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Novel current control scheme with deadbeat algorithm for three-phase current-source active power filter\",\"authors\":\"K. Nishida, Y. Konishi, M. Nakaoka\",\"doi\":\"10.1109/ISIE.2001.931571\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"For an active power filter (APF), the three-phase current source PWM converter is not always used in place of three-phase voltage source PWM converter with voltage regulated DC capacitor. This is due to the difficulty of current control implementation for current source PWM converters. In this paper, an effective method to apply a three-phase current-source PWM converter with a deadbeat controller to an APF is presented. In this APF, the compensation of current harmonics is attained by setting the control purpose, compensating the instantaneous reactive current component in the load current and reducing the ripple in the instantaneous effective current component. In a three-phase current source PWM converter, the time-optimal response of the utility AC grid side input current is two-dimensional finite time settling response, in which two sampling periods are required for a settling time. To cancel this delay, and one more delays caused by the DSP control strategy, a reference value three sampling periods ahead has to be predicted. For this prediction, the reference value detected previously can be useful, because the waveform of harmonic current is periodical in many cases. Finally, it is proven, from an experimental point of view, that the compensating ability of this APF is very high.\",\"PeriodicalId\":124749,\"journal\":{\"name\":\"ISIE 2001. 2001 IEEE International Symposium on Industrial Electronics Proceedings (Cat. No.01TH8570)\",\"volume\":\"40 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-06-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ISIE 2001. 2001 IEEE International Symposium on Industrial Electronics Proceedings (Cat. No.01TH8570)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISIE.2001.931571\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ISIE 2001. 2001 IEEE International Symposium on Industrial Electronics Proceedings (Cat. No.01TH8570)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISIE.2001.931571","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

对于有源电力滤波器(APF)来说,三相电流源PWM变换器并不总是用来代替带稳压直流电容的三相电压源PWM变换器。这是由于电流源PWM变换器的电流控制难以实现。本文提出了一种将带无差拍控制器的三相电流源PWM变换器应用于有源滤波器的有效方法。该有源滤波器通过设定控制目的,补偿负载电流中的瞬时无功电流分量,减小瞬时有效电流分量的纹波,实现对电流谐波的补偿。在三相电流源PWM变换器中,公用事业交流电网侧输入电流的时间最优响应是二维有限时间稳定响应,其中一个稳定时间需要两个采样周期。为了消除这个延迟,以及由DSP控制策略引起的另一个延迟,必须提前三个采样周期预测一个参考值。对于这种预测,由于谐波电流的波形在很多情况下是周期性的,因此先前检测到的参考值是有用的。最后,从实验的角度证明了该有源滤波器具有很高的补偿能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Novel current control scheme with deadbeat algorithm for three-phase current-source active power filter
For an active power filter (APF), the three-phase current source PWM converter is not always used in place of three-phase voltage source PWM converter with voltage regulated DC capacitor. This is due to the difficulty of current control implementation for current source PWM converters. In this paper, an effective method to apply a three-phase current-source PWM converter with a deadbeat controller to an APF is presented. In this APF, the compensation of current harmonics is attained by setting the control purpose, compensating the instantaneous reactive current component in the load current and reducing the ripple in the instantaneous effective current component. In a three-phase current source PWM converter, the time-optimal response of the utility AC grid side input current is two-dimensional finite time settling response, in which two sampling periods are required for a settling time. To cancel this delay, and one more delays caused by the DSP control strategy, a reference value three sampling periods ahead has to be predicted. For this prediction, the reference value detected previously can be useful, because the waveform of harmonic current is periodical in many cases. Finally, it is proven, from an experimental point of view, that the compensating ability of this APF is very high.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信