{"title":"用一对部分已知的标准校准反射计","authors":"A. Arsenovic, R. Weikle, J. Hesler","doi":"10.1109/EUMC.2015.7345766","DOIUrl":null,"url":null,"abstract":"We present a closed form solution to reflectometer self-calibration that allows for two partially known standards. The solution is developed explicitly for a pair lossless reflects standards, but could be applied to any calibration set with similar constraints. Related techniques presented previously are simplified in the new formulation and shown to be special cases of a more general solution. The procedure is based upon the cross-ratio invariance of a Möbius transformation.","PeriodicalId":350086,"journal":{"name":"2015 European Microwave Conference (EuMC)","volume":"204 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reflectometer calibration with a pair of partially known standards\",\"authors\":\"A. Arsenovic, R. Weikle, J. Hesler\",\"doi\":\"10.1109/EUMC.2015.7345766\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We present a closed form solution to reflectometer self-calibration that allows for two partially known standards. The solution is developed explicitly for a pair lossless reflects standards, but could be applied to any calibration set with similar constraints. Related techniques presented previously are simplified in the new formulation and shown to be special cases of a more general solution. The procedure is based upon the cross-ratio invariance of a Möbius transformation.\",\"PeriodicalId\":350086,\"journal\":{\"name\":\"2015 European Microwave Conference (EuMC)\",\"volume\":\"204 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-12-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 European Microwave Conference (EuMC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EUMC.2015.7345766\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 European Microwave Conference (EuMC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EUMC.2015.7345766","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Reflectometer calibration with a pair of partially known standards
We present a closed form solution to reflectometer self-calibration that allows for two partially known standards. The solution is developed explicitly for a pair lossless reflects standards, but could be applied to any calibration set with similar constraints. Related techniques presented previously are simplified in the new formulation and shown to be special cases of a more general solution. The procedure is based upon the cross-ratio invariance of a Möbius transformation.