用一对部分已知的标准校准反射计

A. Arsenovic, R. Weikle, J. Hesler
{"title":"用一对部分已知的标准校准反射计","authors":"A. Arsenovic, R. Weikle, J. Hesler","doi":"10.1109/EUMC.2015.7345766","DOIUrl":null,"url":null,"abstract":"We present a closed form solution to reflectometer self-calibration that allows for two partially known standards. The solution is developed explicitly for a pair lossless reflects standards, but could be applied to any calibration set with similar constraints. Related techniques presented previously are simplified in the new formulation and shown to be special cases of a more general solution. The procedure is based upon the cross-ratio invariance of a Möbius transformation.","PeriodicalId":350086,"journal":{"name":"2015 European Microwave Conference (EuMC)","volume":"204 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reflectometer calibration with a pair of partially known standards\",\"authors\":\"A. Arsenovic, R. Weikle, J. Hesler\",\"doi\":\"10.1109/EUMC.2015.7345766\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We present a closed form solution to reflectometer self-calibration that allows for two partially known standards. The solution is developed explicitly for a pair lossless reflects standards, but could be applied to any calibration set with similar constraints. Related techniques presented previously are simplified in the new formulation and shown to be special cases of a more general solution. The procedure is based upon the cross-ratio invariance of a Möbius transformation.\",\"PeriodicalId\":350086,\"journal\":{\"name\":\"2015 European Microwave Conference (EuMC)\",\"volume\":\"204 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-12-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 European Microwave Conference (EuMC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EUMC.2015.7345766\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 European Microwave Conference (EuMC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EUMC.2015.7345766","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

我们提出了一个封闭形式的解决方案,以反射计自校准,允许两个部分已知的标准。该解决方案是为一对无损反射标准明确开发的,但可以应用于具有类似约束的任何校准集。先前提出的相关技术在新的公式中进行了简化,并显示为更一般解的特殊情况。该过程基于Möbius变换的交叉比率不变性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Reflectometer calibration with a pair of partially known standards
We present a closed form solution to reflectometer self-calibration that allows for two partially known standards. The solution is developed explicitly for a pair lossless reflects standards, but could be applied to any calibration set with similar constraints. Related techniques presented previously are simplified in the new formulation and shown to be special cases of a more general solution. The procedure is based upon the cross-ratio invariance of a Möbius transformation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信