使用个人数字辅助的便携式尿动力学监测系统

K. Kim, Y. An, C.G. Song
{"title":"使用个人数字辅助的便携式尿动力学监测系统","authors":"K. Kim, Y. An, C.G. Song","doi":"10.1109/ISITC.2007.72","DOIUrl":null,"url":null,"abstract":"The conventional urodynamic monitoring is performed by filling artificially the bladder with saline. It is difficult to evaluate the physiological functions of the storage and voiding of the bladder. In this study, we constructed an ambulatory urodynamic monitoring (AUM) system and proposed a novel method for estimating abdominal pressure by bio-impedance changes and EMG activity. The system was evaluated in 10 patients. As the intensity of the abdomen contraction increased, the amplitude of bio-impedance signal and the RMS value of EMG increased as compared to those observed during resting. The correlation coefficient was 0.72 for the \"weak\" contraction, 0.96 for \"strong\" contraction, 0.90 for \"stronger\" contraction, 0.84 for \"vigorous\" contraction and 0.78 for \"maximal\" contraction. Also, daily events such as coughing, sneezing and conversation, were sensitively monitored by observing the amplitude change of the bio-impedance signals. However, the EMG signals could not be used to detect these events, therefore, we determined that bio- impedance method was a more useful tool to measure the changes of abdominal pressure noninvasively for urodynamic monitoring.","PeriodicalId":394071,"journal":{"name":"2007 International Symposium on Information Technology Convergence (ISITC 2007)","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-11-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Portable Urodynamics Monitoring System Using a Personal Digital Assistance\",\"authors\":\"K. Kim, Y. An, C.G. Song\",\"doi\":\"10.1109/ISITC.2007.72\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The conventional urodynamic monitoring is performed by filling artificially the bladder with saline. It is difficult to evaluate the physiological functions of the storage and voiding of the bladder. In this study, we constructed an ambulatory urodynamic monitoring (AUM) system and proposed a novel method for estimating abdominal pressure by bio-impedance changes and EMG activity. The system was evaluated in 10 patients. As the intensity of the abdomen contraction increased, the amplitude of bio-impedance signal and the RMS value of EMG increased as compared to those observed during resting. The correlation coefficient was 0.72 for the \\\"weak\\\" contraction, 0.96 for \\\"strong\\\" contraction, 0.90 for \\\"stronger\\\" contraction, 0.84 for \\\"vigorous\\\" contraction and 0.78 for \\\"maximal\\\" contraction. Also, daily events such as coughing, sneezing and conversation, were sensitively monitored by observing the amplitude change of the bio-impedance signals. However, the EMG signals could not be used to detect these events, therefore, we determined that bio- impedance method was a more useful tool to measure the changes of abdominal pressure noninvasively for urodynamic monitoring.\",\"PeriodicalId\":394071,\"journal\":{\"name\":\"2007 International Symposium on Information Technology Convergence (ISITC 2007)\",\"volume\":\"36 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-11-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 International Symposium on Information Technology Convergence (ISITC 2007)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISITC.2007.72\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 International Symposium on Information Technology Convergence (ISITC 2007)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISITC.2007.72","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

传统的尿动力学监测是通过人工向膀胱内注入生理盐水来进行的。膀胱储尿的生理功能难以评价。在这项研究中,我们构建了一个动态尿动力学监测(AUM)系统,并提出了一种通过生物阻抗变化和肌电图活动估计腹部压力的新方法。该系统在10例患者中进行了评估。随着腹部收缩强度的增加,生物阻抗信号幅度和肌电均方根值较静息时有所增加。“弱”收缩的相关系数为0.72,“强”收缩的相关系数为0.96,“强”收缩的相关系数为0.90,“剧烈”收缩的相关系数为0.84,“最大”收缩的相关系数为0.78。此外,通过观察生物阻抗信号的振幅变化,对咳嗽、打喷嚏和谈话等日常活动进行敏感监测。然而,肌电图信号不能用于检测这些事件,因此,我们认为生物阻抗法是一种更有用的工具,可以无创地测量腹压变化,用于尿动力学监测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Portable Urodynamics Monitoring System Using a Personal Digital Assistance
The conventional urodynamic monitoring is performed by filling artificially the bladder with saline. It is difficult to evaluate the physiological functions of the storage and voiding of the bladder. In this study, we constructed an ambulatory urodynamic monitoring (AUM) system and proposed a novel method for estimating abdominal pressure by bio-impedance changes and EMG activity. The system was evaluated in 10 patients. As the intensity of the abdomen contraction increased, the amplitude of bio-impedance signal and the RMS value of EMG increased as compared to those observed during resting. The correlation coefficient was 0.72 for the "weak" contraction, 0.96 for "strong" contraction, 0.90 for "stronger" contraction, 0.84 for "vigorous" contraction and 0.78 for "maximal" contraction. Also, daily events such as coughing, sneezing and conversation, were sensitively monitored by observing the amplitude change of the bio-impedance signals. However, the EMG signals could not be used to detect these events, therefore, we determined that bio- impedance method was a more useful tool to measure the changes of abdominal pressure noninvasively for urodynamic monitoring.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信