Shuichi Ye, Guowei Zhang, Xilian Wang, Dajin Wang, Z. Liu
{"title":"二维平面阵列热成像传感器的研究与制备","authors":"Shuichi Ye, Guowei Zhang, Xilian Wang, Dajin Wang, Z. Liu","doi":"10.1109/ICT.2001.979937","DOIUrl":null,"url":null,"abstract":"Infrared imaging systems have been applied widely, and developed step by step with improved performance of infrared image devices. Although a thermocouple prepared by high quality thermoelectric materials has already been used as thermoelectric detectors, it is of new exploration when used as units of two-dimensional plane array thermal imaging sensors. In this paper, the working principle, device design, manufacturing process, device performance and measurement of two-dimensional plane array sensors are introduced and given in detail. The prepared thermal imaging sensors with 10 /spl times/ 10 pixels in 20 /spl times/ 20 mm/sup 2/ are made up of thermocouples with a single pixel of dimension of 0.4 /spl times/ 0.4 /spl times/ 0.15 mm/sup 3/ and prepared by pseudo-ternary BiTe thermoelectric materials with figure of merits Z=3.09 /spl times/ 10/sup -3/ K. The unit area for accepting thermal radiation is 1.9 /spl times/ 1.9 mm/sup 2/. The performance of the pixels and their uniformity in the arrays is measured respectively. From measurements, the maximum responsivity 0.12 V/W, detectability D* 1.17 /spl times/ 10 Hz/sup 1/2//W and responsive-time 24 ms of the thermal image arrays are obtained. The experimental results and theoretical analyses were compared, based on which, new ways for improving two-dimensional plane arrays thermal imaging sensors are proposed in this paper.","PeriodicalId":203601,"journal":{"name":"Proceedings ICT2001. 20 International Conference on Thermoelectrics (Cat. No.01TH8589)","volume":"32 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-06-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Research and preparation of two-dimensional plane arrays thermal imaging sensor\",\"authors\":\"Shuichi Ye, Guowei Zhang, Xilian Wang, Dajin Wang, Z. Liu\",\"doi\":\"10.1109/ICT.2001.979937\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Infrared imaging systems have been applied widely, and developed step by step with improved performance of infrared image devices. Although a thermocouple prepared by high quality thermoelectric materials has already been used as thermoelectric detectors, it is of new exploration when used as units of two-dimensional plane array thermal imaging sensors. In this paper, the working principle, device design, manufacturing process, device performance and measurement of two-dimensional plane array sensors are introduced and given in detail. The prepared thermal imaging sensors with 10 /spl times/ 10 pixels in 20 /spl times/ 20 mm/sup 2/ are made up of thermocouples with a single pixel of dimension of 0.4 /spl times/ 0.4 /spl times/ 0.15 mm/sup 3/ and prepared by pseudo-ternary BiTe thermoelectric materials with figure of merits Z=3.09 /spl times/ 10/sup -3/ K. The unit area for accepting thermal radiation is 1.9 /spl times/ 1.9 mm/sup 2/. The performance of the pixels and their uniformity in the arrays is measured respectively. From measurements, the maximum responsivity 0.12 V/W, detectability D* 1.17 /spl times/ 10 Hz/sup 1/2//W and responsive-time 24 ms of the thermal image arrays are obtained. The experimental results and theoretical analyses were compared, based on which, new ways for improving two-dimensional plane arrays thermal imaging sensors are proposed in this paper.\",\"PeriodicalId\":203601,\"journal\":{\"name\":\"Proceedings ICT2001. 20 International Conference on Thermoelectrics (Cat. No.01TH8589)\",\"volume\":\"32 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-06-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings ICT2001. 20 International Conference on Thermoelectrics (Cat. No.01TH8589)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICT.2001.979937\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings ICT2001. 20 International Conference on Thermoelectrics (Cat. No.01TH8589)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICT.2001.979937","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Research and preparation of two-dimensional plane arrays thermal imaging sensor
Infrared imaging systems have been applied widely, and developed step by step with improved performance of infrared image devices. Although a thermocouple prepared by high quality thermoelectric materials has already been used as thermoelectric detectors, it is of new exploration when used as units of two-dimensional plane array thermal imaging sensors. In this paper, the working principle, device design, manufacturing process, device performance and measurement of two-dimensional plane array sensors are introduced and given in detail. The prepared thermal imaging sensors with 10 /spl times/ 10 pixels in 20 /spl times/ 20 mm/sup 2/ are made up of thermocouples with a single pixel of dimension of 0.4 /spl times/ 0.4 /spl times/ 0.15 mm/sup 3/ and prepared by pseudo-ternary BiTe thermoelectric materials with figure of merits Z=3.09 /spl times/ 10/sup -3/ K. The unit area for accepting thermal radiation is 1.9 /spl times/ 1.9 mm/sup 2/. The performance of the pixels and their uniformity in the arrays is measured respectively. From measurements, the maximum responsivity 0.12 V/W, detectability D* 1.17 /spl times/ 10 Hz/sup 1/2//W and responsive-time 24 ms of the thermal image arrays are obtained. The experimental results and theoretical analyses were compared, based on which, new ways for improving two-dimensional plane arrays thermal imaging sensors are proposed in this paper.