{"title":"应用于小型风力发电机的直流/交流变换器控制算法","authors":"P. Mlodzikowski, A. Milczarek, M. Malinowski","doi":"10.1109/ISIE.2011.5984297","DOIUrl":null,"url":null,"abstract":"Paper in detail presents control algorithm of a DC/AC converter applied in a small wind turbine (SWT), which has grid connected and a stand-alone operation mode. Common problems encountered SWT's transient between modes are described. Algorithm was implemented using a digital signal processor (DSP) control platform and tested using a lab setup with a 2.2 kW permanent magnet synchronous generator (PMSG). That type of generator is popular among SWTs. Results obtained from experimental verification are included.","PeriodicalId":162453,"journal":{"name":"2011 IEEE International Symposium on Industrial Electronics","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Control algorithm of a DC/AC converter applied in a small wind turbine\",\"authors\":\"P. Mlodzikowski, A. Milczarek, M. Malinowski\",\"doi\":\"10.1109/ISIE.2011.5984297\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Paper in detail presents control algorithm of a DC/AC converter applied in a small wind turbine (SWT), which has grid connected and a stand-alone operation mode. Common problems encountered SWT's transient between modes are described. Algorithm was implemented using a digital signal processor (DSP) control platform and tested using a lab setup with a 2.2 kW permanent magnet synchronous generator (PMSG). That type of generator is popular among SWTs. Results obtained from experimental verification are included.\",\"PeriodicalId\":162453,\"journal\":{\"name\":\"2011 IEEE International Symposium on Industrial Electronics\",\"volume\":\"22 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-06-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 IEEE International Symposium on Industrial Electronics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISIE.2011.5984297\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE International Symposium on Industrial Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISIE.2011.5984297","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Control algorithm of a DC/AC converter applied in a small wind turbine
Paper in detail presents control algorithm of a DC/AC converter applied in a small wind turbine (SWT), which has grid connected and a stand-alone operation mode. Common problems encountered SWT's transient between modes are described. Algorithm was implemented using a digital signal processor (DSP) control platform and tested using a lab setup with a 2.2 kW permanent magnet synchronous generator (PMSG). That type of generator is popular among SWTs. Results obtained from experimental verification are included.