{"title":"高压输电线的高频特性","authors":"N. Suljanovic, A. Mujčić, M. Zajc, J. Tasic","doi":"10.1109/EURCON.2003.1248206","DOIUrl":null,"url":null,"abstract":"This paper presents a major high-frequency characteristic of high-voltage overhead power line: amplitude characteristics, group delay and noise characteristics. Since measurements of high-frequency power-line characteristics are rare due to permission of power utilities for access to power lines, computer simulations have a crucial role in design of communication systems via power lines. Simulated high-frequency and noise characteristics of 400 kV power line are presented and compared with measurements on actual power line.","PeriodicalId":337983,"journal":{"name":"The IEEE Region 8 EUROCON 2003. Computer as a Tool.","volume":"187 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-12-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"23","resultStr":"{\"title\":\"High-frequency characteristics of high-voltage power line\",\"authors\":\"N. Suljanovic, A. Mujčić, M. Zajc, J. Tasic\",\"doi\":\"10.1109/EURCON.2003.1248206\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a major high-frequency characteristic of high-voltage overhead power line: amplitude characteristics, group delay and noise characteristics. Since measurements of high-frequency power-line characteristics are rare due to permission of power utilities for access to power lines, computer simulations have a crucial role in design of communication systems via power lines. Simulated high-frequency and noise characteristics of 400 kV power line are presented and compared with measurements on actual power line.\",\"PeriodicalId\":337983,\"journal\":{\"name\":\"The IEEE Region 8 EUROCON 2003. Computer as a Tool.\",\"volume\":\"187 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-12-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"23\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The IEEE Region 8 EUROCON 2003. Computer as a Tool.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EURCON.2003.1248206\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The IEEE Region 8 EUROCON 2003. Computer as a Tool.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EURCON.2003.1248206","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
High-frequency characteristics of high-voltage power line
This paper presents a major high-frequency characteristic of high-voltage overhead power line: amplitude characteristics, group delay and noise characteristics. Since measurements of high-frequency power-line characteristics are rare due to permission of power utilities for access to power lines, computer simulations have a crucial role in design of communication systems via power lines. Simulated high-frequency and noise characteristics of 400 kV power line are presented and compared with measurements on actual power line.