{"title":"使用标称工作点作为增益预定控制器的设计变量","authors":"R. C. Martin, S. Kramer","doi":"10.1109/NAECON.1995.521983","DOIUrl":null,"url":null,"abstract":"One approach to designing gain scheduled controllers is to decompose them into an inner loop scheduled so that the closed inner loop response is as close as possible to some nominal plant response and an unscheduled outer loop designed using the nominal plant. The choice of nominal plant/operating point is traditionally based on engineering judgment and experience. Rather than the usual approach of designing controllers for several operating points and interpolating between them, the authors have proposed a different procedure in which the parametric form of the controller is specified and parameter values are directly computed to minimize deviation from nominal over the entire operating range. This work presents an extension in which the nominal operating point is allowed to vary as an additional design variable in the optimization. This approach is applied to design of the F-18 longitudinal controller inner equalization loop. The resulting controller has significantly better consistency as compared to an existing design created using the old approach.","PeriodicalId":171918,"journal":{"name":"Proceedings of the IEEE 1995 National Aerospace and Electronics Conference. NAECON 1995","volume":"117 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Using the nominal operating point as a design variable for gain scheduled controllers\",\"authors\":\"R. C. Martin, S. Kramer\",\"doi\":\"10.1109/NAECON.1995.521983\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"One approach to designing gain scheduled controllers is to decompose them into an inner loop scheduled so that the closed inner loop response is as close as possible to some nominal plant response and an unscheduled outer loop designed using the nominal plant. The choice of nominal plant/operating point is traditionally based on engineering judgment and experience. Rather than the usual approach of designing controllers for several operating points and interpolating between them, the authors have proposed a different procedure in which the parametric form of the controller is specified and parameter values are directly computed to minimize deviation from nominal over the entire operating range. This work presents an extension in which the nominal operating point is allowed to vary as an additional design variable in the optimization. This approach is applied to design of the F-18 longitudinal controller inner equalization loop. The resulting controller has significantly better consistency as compared to an existing design created using the old approach.\",\"PeriodicalId\":171918,\"journal\":{\"name\":\"Proceedings of the IEEE 1995 National Aerospace and Electronics Conference. NAECON 1995\",\"volume\":\"117 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-05-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the IEEE 1995 National Aerospace and Electronics Conference. NAECON 1995\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NAECON.1995.521983\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the IEEE 1995 National Aerospace and Electronics Conference. NAECON 1995","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NAECON.1995.521983","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

设计增益计划控制器的一种方法是将其分解为一个计划的内环,使封闭的内环响应尽可能接近某个标称植物响应,并使用标称植物设计一个非计划的外环。标称工厂/工作点的选择传统上是基于工程判断和经验。与通常为几个工作点设计控制器并在它们之间进行插值的方法不同,作者提出了一种不同的方法,其中指定控制器的参数形式并直接计算参数值以最小化整个工作范围内标称偏差。这项工作提出了一个扩展,其中标称工作点被允许作为一个额外的设计变量在优化变化。将该方法应用于F-18纵向控制器内部均衡回路的设计。与使用旧方法创建的现有设计相比,生成的控制器具有明显更好的一致性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Using the nominal operating point as a design variable for gain scheduled controllers
One approach to designing gain scheduled controllers is to decompose them into an inner loop scheduled so that the closed inner loop response is as close as possible to some nominal plant response and an unscheduled outer loop designed using the nominal plant. The choice of nominal plant/operating point is traditionally based on engineering judgment and experience. Rather than the usual approach of designing controllers for several operating points and interpolating between them, the authors have proposed a different procedure in which the parametric form of the controller is specified and parameter values are directly computed to minimize deviation from nominal over the entire operating range. This work presents an extension in which the nominal operating point is allowed to vary as an additional design variable in the optimization. This approach is applied to design of the F-18 longitudinal controller inner equalization loop. The resulting controller has significantly better consistency as compared to an existing design created using the old approach.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信