Ying Wang, S. Quan, Liang Huang, Kang-Chin Yang, Ying Xiong, J. Quan
{"title":"三相并网逆变器电流预测控制的研究与改进","authors":"Ying Wang, S. Quan, Liang Huang, Kang-Chin Yang, Ying Xiong, J. Quan","doi":"10.1109/YAC.2017.7967379","DOIUrl":null,"url":null,"abstract":"According to the characteristics of high performance three-phase grid-connected inverters, the strategy of model current predictive control for three-phase grid-connected inverters without PLL is put forward. In each control cycle, the eight voltage vectors of three-phase grid-connected Inverters are calculated in prediction model. The voltage vector which makes the value function minimum is taken as the switching vector of the next cycle. Thus, d axis component and q axis component own independent control and tracked fast. By the non-phase locked loop strategy, the trigonometric function values of the grid could be directly calculating, which avoids the delay of phase detection of PLL. Simulation results show that the three-Phase Grid-Connected Inverters that take model Current Predictive Control without PLL as control strategy possess nice static performance and better dynamic performance.","PeriodicalId":232358,"journal":{"name":"2017 32nd Youth Academic Annual Conference of Chinese Association of Automation (YAC)","volume":"61 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-05-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Research and improvement of current predictive control for the three-phase grid connected inverter\",\"authors\":\"Ying Wang, S. Quan, Liang Huang, Kang-Chin Yang, Ying Xiong, J. Quan\",\"doi\":\"10.1109/YAC.2017.7967379\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"According to the characteristics of high performance three-phase grid-connected inverters, the strategy of model current predictive control for three-phase grid-connected inverters without PLL is put forward. In each control cycle, the eight voltage vectors of three-phase grid-connected Inverters are calculated in prediction model. The voltage vector which makes the value function minimum is taken as the switching vector of the next cycle. Thus, d axis component and q axis component own independent control and tracked fast. By the non-phase locked loop strategy, the trigonometric function values of the grid could be directly calculating, which avoids the delay of phase detection of PLL. Simulation results show that the three-Phase Grid-Connected Inverters that take model Current Predictive Control without PLL as control strategy possess nice static performance and better dynamic performance.\",\"PeriodicalId\":232358,\"journal\":{\"name\":\"2017 32nd Youth Academic Annual Conference of Chinese Association of Automation (YAC)\",\"volume\":\"61 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-05-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 32nd Youth Academic Annual Conference of Chinese Association of Automation (YAC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/YAC.2017.7967379\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 32nd Youth Academic Annual Conference of Chinese Association of Automation (YAC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/YAC.2017.7967379","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Research and improvement of current predictive control for the three-phase grid connected inverter
According to the characteristics of high performance three-phase grid-connected inverters, the strategy of model current predictive control for three-phase grid-connected inverters without PLL is put forward. In each control cycle, the eight voltage vectors of three-phase grid-connected Inverters are calculated in prediction model. The voltage vector which makes the value function minimum is taken as the switching vector of the next cycle. Thus, d axis component and q axis component own independent control and tracked fast. By the non-phase locked loop strategy, the trigonometric function values of the grid could be directly calculating, which avoids the delay of phase detection of PLL. Simulation results show that the three-Phase Grid-Connected Inverters that take model Current Predictive Control without PLL as control strategy possess nice static performance and better dynamic performance.