N. Starodub, Igor P. Goraychuk, V. M. Starodub, V. V. Il’chenko, G. V. Kuznetsov
{"title":"一种新的电测量方法在生物分子间相互作用研究中的应用","authors":"N. Starodub, Igor P. Goraychuk, V. M. Starodub, V. V. Il’chenko, G. V. Kuznetsov","doi":"10.1117/12.382319","DOIUrl":null,"url":null,"abstract":"In the paper the results about changes of the current- voltage characteristics of the surface-barrier structures (SBS) after the deposition of myoglobin and its specific monoclonal antibodies are presented. It was shown that the SBS structures with ultra-thin films or with ultra-thin layer of the porous silicon are sensitive to the presence of the protein or its specific immune complex on their surfaces. The response of the system depended on the conditions of the specific complex formation. The characteristic optimum of the thickness of Ni film or the layer of the porous silicon was revealed when the changes of the I-V characteristics had a maximum level.","PeriodicalId":318748,"journal":{"name":"Design, Test, Integration, and Packaging of MEMS/MOEMS","volume":"271 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-04-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Application of a new electrometric approach to study interaction between biological molecules\",\"authors\":\"N. Starodub, Igor P. Goraychuk, V. M. Starodub, V. V. Il’chenko, G. V. Kuznetsov\",\"doi\":\"10.1117/12.382319\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the paper the results about changes of the current- voltage characteristics of the surface-barrier structures (SBS) after the deposition of myoglobin and its specific monoclonal antibodies are presented. It was shown that the SBS structures with ultra-thin films or with ultra-thin layer of the porous silicon are sensitive to the presence of the protein or its specific immune complex on their surfaces. The response of the system depended on the conditions of the specific complex formation. The characteristic optimum of the thickness of Ni film or the layer of the porous silicon was revealed when the changes of the I-V characteristics had a maximum level.\",\"PeriodicalId\":318748,\"journal\":{\"name\":\"Design, Test, Integration, and Packaging of MEMS/MOEMS\",\"volume\":\"271 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-04-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Design, Test, Integration, and Packaging of MEMS/MOEMS\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.382319\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Design, Test, Integration, and Packaging of MEMS/MOEMS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.382319","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Application of a new electrometric approach to study interaction between biological molecules
In the paper the results about changes of the current- voltage characteristics of the surface-barrier structures (SBS) after the deposition of myoglobin and its specific monoclonal antibodies are presented. It was shown that the SBS structures with ultra-thin films or with ultra-thin layer of the porous silicon are sensitive to the presence of the protein or its specific immune complex on their surfaces. The response of the system depended on the conditions of the specific complex formation. The characteristic optimum of the thickness of Ni film or the layer of the porous silicon was revealed when the changes of the I-V characteristics had a maximum level.