减少全身扫描中的运动伪影

H. Daanen, M. A. Brunsman, K. Robinette
{"title":"减少全身扫描中的运动伪影","authors":"H. Daanen, M. A. Brunsman, K. Robinette","doi":"10.1109/IM.1997.603874","DOIUrl":null,"url":null,"abstract":"Movement artifacts during whole body scanning are a major concern when reproducible results are required. To determine the magnitude of the artifacts, 11 subjects were scanned with and without a positioning device on the head. The sway of the body was determined by a force plate. It was shown that the pointer on the head reduced the magnitude of the forward/backward sway by over 50%. The resulting standard deviation is less than the resolution of the scanner. Movement artifacts within the body, like head rotation, are hard to control. Again, the pointer on the head assists in reducing the artifacts. The ventilation depth during the scan determines the shape of the chest and should be standardized to get reproducible results.","PeriodicalId":337843,"journal":{"name":"Proceedings. International Conference on Recent Advances in 3-D Digital Imaging and Modeling (Cat. No.97TB100134)","volume":"432 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1997-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"39","resultStr":"{\"title\":\"Reducing movement artifacts in whole body scanning\",\"authors\":\"H. Daanen, M. A. Brunsman, K. Robinette\",\"doi\":\"10.1109/IM.1997.603874\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Movement artifacts during whole body scanning are a major concern when reproducible results are required. To determine the magnitude of the artifacts, 11 subjects were scanned with and without a positioning device on the head. The sway of the body was determined by a force plate. It was shown that the pointer on the head reduced the magnitude of the forward/backward sway by over 50%. The resulting standard deviation is less than the resolution of the scanner. Movement artifacts within the body, like head rotation, are hard to control. Again, the pointer on the head assists in reducing the artifacts. The ventilation depth during the scan determines the shape of the chest and should be standardized to get reproducible results.\",\"PeriodicalId\":337843,\"journal\":{\"name\":\"Proceedings. International Conference on Recent Advances in 3-D Digital Imaging and Modeling (Cat. No.97TB100134)\",\"volume\":\"432 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-05-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"39\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings. International Conference on Recent Advances in 3-D Digital Imaging and Modeling (Cat. No.97TB100134)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IM.1997.603874\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings. International Conference on Recent Advances in 3-D Digital Imaging and Modeling (Cat. No.97TB100134)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IM.1997.603874","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 39

摘要

当需要重现结果时,全身扫描过程中的运动伪影是一个主要问题。为了确定伪影的大小,11名受试者分别在头部安装和不安装定位装置时接受了扫描。身体的摆动是由测力板决定的。结果表明,头部的指针减少了50%以上的前后摇摆幅度。得到的标准偏差小于扫描仪的分辨率。身体内部的运动产物,比如头部旋转,很难控制。同样,头部的指针有助于减少伪影。扫描时的通气深度决定了胸部的形状,应该标准化以获得可重复的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Reducing movement artifacts in whole body scanning
Movement artifacts during whole body scanning are a major concern when reproducible results are required. To determine the magnitude of the artifacts, 11 subjects were scanned with and without a positioning device on the head. The sway of the body was determined by a force plate. It was shown that the pointer on the head reduced the magnitude of the forward/backward sway by over 50%. The resulting standard deviation is less than the resolution of the scanner. Movement artifacts within the body, like head rotation, are hard to control. Again, the pointer on the head assists in reducing the artifacts. The ventilation depth during the scan determines the shape of the chest and should be standardized to get reproducible results.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信