海洋遥感地基微波辐射计设计与实时定标

Yu Zhang, Shengwei Zhang, Yingzhu Huang, Jieying He, F. Sun
{"title":"海洋遥感地基微波辐射计设计与实时定标","authors":"Yu Zhang, Shengwei Zhang, Yingzhu Huang, Jieying He, F. Sun","doi":"10.1109/ISSSE.2010.5607099","DOIUrl":null,"url":null,"abstract":"A multi-frequency, ground-based microwave radiometer (MWR) for ocean remote sensing has been designed and developed in this paper. It will be used on the offshore oil platform and provide atmospheric soundings of physical temperature and liquid water vapor using channels in the oxygen resonance band (6.8GHz) and water vapor resonance band (23.8GHz). The other channels at 10.7GHz, 18.7GHz and 37GHz are used as atmospheric windows, each with dual polarization. The measurements at various combinations of these frequencies and polarization will obtain many geophysical parameters such as the sea-surface temperature, near-surface wind speed, sea ice types and so on. The multi-frequency microwave radiometer is a five frequencies, ten channels and linear polarization system. The receiver is working at total-power mode with super heterodyne style. And the data processing and system control unit is used of operating mode control, data acquisition and digitizing, automatic gain control, state control of the radiometer system and communication with the remote computer system by asynchronous serial interface. Besides, an absolute calibration and a quasi-real-time calibration method used in the multi-frequency MWR are presented and the relative result is also discussed, which guaranteed the high resolution of the multi-frequency microwave radiometer system.","PeriodicalId":211786,"journal":{"name":"2010 International Symposium on Signals, Systems and Electronics","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ground-based microwave radiometer design and real-time calibration for ocean remote sensing\",\"authors\":\"Yu Zhang, Shengwei Zhang, Yingzhu Huang, Jieying He, F. Sun\",\"doi\":\"10.1109/ISSSE.2010.5607099\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A multi-frequency, ground-based microwave radiometer (MWR) for ocean remote sensing has been designed and developed in this paper. It will be used on the offshore oil platform and provide atmospheric soundings of physical temperature and liquid water vapor using channels in the oxygen resonance band (6.8GHz) and water vapor resonance band (23.8GHz). The other channels at 10.7GHz, 18.7GHz and 37GHz are used as atmospheric windows, each with dual polarization. The measurements at various combinations of these frequencies and polarization will obtain many geophysical parameters such as the sea-surface temperature, near-surface wind speed, sea ice types and so on. The multi-frequency microwave radiometer is a five frequencies, ten channels and linear polarization system. The receiver is working at total-power mode with super heterodyne style. And the data processing and system control unit is used of operating mode control, data acquisition and digitizing, automatic gain control, state control of the radiometer system and communication with the remote computer system by asynchronous serial interface. Besides, an absolute calibration and a quasi-real-time calibration method used in the multi-frequency MWR are presented and the relative result is also discussed, which guaranteed the high resolution of the multi-frequency microwave radiometer system.\",\"PeriodicalId\":211786,\"journal\":{\"name\":\"2010 International Symposium on Signals, Systems and Electronics\",\"volume\":\"7 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-10-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 International Symposium on Signals, Systems and Electronics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISSSE.2010.5607099\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 International Symposium on Signals, Systems and Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISSSE.2010.5607099","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

设计并研制了一种用于海洋遥感的多频地面微波辐射计。它将用于海洋石油平台,利用氧共振带(6.8GHz)和水蒸气共振带(23.8GHz)通道提供物理温度和液态水蒸汽的大气探测。在10.7GHz、18.7GHz和37GHz的其他信道用作大气窗口,每个信道都具有双极化。在这些频率和极化的不同组合下进行测量,可以得到许多地球物理参数,如海面温度、近地面风速、海冰类型等。多频微波辐射计是一个五频十通道线性极化系统。接收机工作在超外差式全功率模式下。数据处理和系统控制单元主要实现了辐射计系统的工作模式控制、数据采集与数字化、自动增益控制、状态控制等功能,并通过异步串行接口与远程计算机系统通信。提出了多频微波辐射计系统的绝对定标方法和准实时定标方法,并对定标结果进行了讨论,保证了多频微波辐射计系统的高分辨率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Ground-based microwave radiometer design and real-time calibration for ocean remote sensing
A multi-frequency, ground-based microwave radiometer (MWR) for ocean remote sensing has been designed and developed in this paper. It will be used on the offshore oil platform and provide atmospheric soundings of physical temperature and liquid water vapor using channels in the oxygen resonance band (6.8GHz) and water vapor resonance band (23.8GHz). The other channels at 10.7GHz, 18.7GHz and 37GHz are used as atmospheric windows, each with dual polarization. The measurements at various combinations of these frequencies and polarization will obtain many geophysical parameters such as the sea-surface temperature, near-surface wind speed, sea ice types and so on. The multi-frequency microwave radiometer is a five frequencies, ten channels and linear polarization system. The receiver is working at total-power mode with super heterodyne style. And the data processing and system control unit is used of operating mode control, data acquisition and digitizing, automatic gain control, state control of the radiometer system and communication with the remote computer system by asynchronous serial interface. Besides, an absolute calibration and a quasi-real-time calibration method used in the multi-frequency MWR are presented and the relative result is also discussed, which guaranteed the high resolution of the multi-frequency microwave radiometer system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信