无电池无线通信系统通过人体进行体内医疗芯片

Tomohiro Yamada, T. Uezono, H. Sugawara, K. Okada, K. Masu, A. Oki, Y. Horiike
{"title":"无电池无线通信系统通过人体进行体内医疗芯片","authors":"Tomohiro Yamada, T. Uezono, H. Sugawara, K. Okada, K. Masu, A. Oki, Y. Horiike","doi":"10.1109/SMIC.2004.1398235","DOIUrl":null,"url":null,"abstract":"This paper proposes a battery-less wireless communication system for in-vivo healthcare chip. We measured attenuation characteristics through a human body equivalent for six frequencies. Measured attenuation of 13.56 MHz is 47 dB through 15 cm thickness of human body equivalent. It is too difficult to use the usual modulations under such low power consumption. Then, we implemented the proposed system using the 13-56 MHz band with pulse interval modulation (PIM). In the simulated result, 16 mV of output voltage can be obtained at the outside receiver when coupling factor is 0.1. We also investigate antenna structure, and a tablet structure is suitable for the proposed system.","PeriodicalId":288561,"journal":{"name":"Digest of Papers. 2004 Topical Meeting onSilicon Monolithic Integrated Circuits in RF Systems, 2004.","volume":"81 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-09-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":"{\"title\":\"Battery-less wireless communication system through human body for in-vivo healthcare chip\",\"authors\":\"Tomohiro Yamada, T. Uezono, H. Sugawara, K. Okada, K. Masu, A. Oki, Y. Horiike\",\"doi\":\"10.1109/SMIC.2004.1398235\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a battery-less wireless communication system for in-vivo healthcare chip. We measured attenuation characteristics through a human body equivalent for six frequencies. Measured attenuation of 13.56 MHz is 47 dB through 15 cm thickness of human body equivalent. It is too difficult to use the usual modulations under such low power consumption. Then, we implemented the proposed system using the 13-56 MHz band with pulse interval modulation (PIM). In the simulated result, 16 mV of output voltage can be obtained at the outside receiver when coupling factor is 0.1. We also investigate antenna structure, and a tablet structure is suitable for the proposed system.\",\"PeriodicalId\":288561,\"journal\":{\"name\":\"Digest of Papers. 2004 Topical Meeting onSilicon Monolithic Integrated Circuits in RF Systems, 2004.\",\"volume\":\"81 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-09-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Digest of Papers. 2004 Topical Meeting onSilicon Monolithic Integrated Circuits in RF Systems, 2004.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SMIC.2004.1398235\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digest of Papers. 2004 Topical Meeting onSilicon Monolithic Integrated Circuits in RF Systems, 2004.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SMIC.2004.1398235","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

摘要

提出了一种体内医疗芯片的无电池无线通信系统。我们通过人体等效测量了六个频率的衰减特性。测量到的13.56 MHz的衰减相当于47 dB通过15 cm厚度的人体。在如此低的功耗下,使用常规调制太难了。然后,我们使用13-56 MHz带脉冲间隔调制(PIM)实现了所提出的系统。仿真结果表明,耦合系数为0.1时,外接收机输出电压可达16 mV。我们还对天线结构进行了研究,认为平板结构适合于所提出的系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Battery-less wireless communication system through human body for in-vivo healthcare chip
This paper proposes a battery-less wireless communication system for in-vivo healthcare chip. We measured attenuation characteristics through a human body equivalent for six frequencies. Measured attenuation of 13.56 MHz is 47 dB through 15 cm thickness of human body equivalent. It is too difficult to use the usual modulations under such low power consumption. Then, we implemented the proposed system using the 13-56 MHz band with pulse interval modulation (PIM). In the simulated result, 16 mV of output voltage can be obtained at the outside receiver when coupling factor is 0.1. We also investigate antenna structure, and a tablet structure is suitable for the proposed system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信