J. Van Coller, A. Beutel, N. Maphalala, F. Endrejat, J. Msimango
{"title":"低压ASD供电侧熔断器因中压电机熔断器操作而失效","authors":"J. Van Coller, A. Beutel, N. Maphalala, F. Endrejat, J. Msimango","doi":"10.1109/ICIT.2006.372476","DOIUrl":null,"url":null,"abstract":"Transients in MV networks due to MV motor fuse operation can propagate through MV/LV transformers to LV networks. The LV surges can then cause the high-speed fuses protecting LV adjustable speed drives (ASDs) to operate and this can disrupt production. LV ASDs often include supply-side reactors to make them less susceptible to surges (in particular capacitor-switching surges). For the network studied, these reactors did not prevent operation of the particular ASD highspeed fuses. One possible reason was that the supply-side reactors were saturating during the surge conditions associated with MV fuse operation. This paper describes the investigation that included initial measurements, a simulation study so that various proposed solutions could be compared, and final measurements with the final recommended solution in place -supply-side reactors that did not saturate during these surge conditions.","PeriodicalId":103105,"journal":{"name":"2006 IEEE International Conference on Industrial Technology","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Failure of LV ASD supply-side fuses due to MV motor fuse operation\",\"authors\":\"J. Van Coller, A. Beutel, N. Maphalala, F. Endrejat, J. Msimango\",\"doi\":\"10.1109/ICIT.2006.372476\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Transients in MV networks due to MV motor fuse operation can propagate through MV/LV transformers to LV networks. The LV surges can then cause the high-speed fuses protecting LV adjustable speed drives (ASDs) to operate and this can disrupt production. LV ASDs often include supply-side reactors to make them less susceptible to surges (in particular capacitor-switching surges). For the network studied, these reactors did not prevent operation of the particular ASD highspeed fuses. One possible reason was that the supply-side reactors were saturating during the surge conditions associated with MV fuse operation. This paper describes the investigation that included initial measurements, a simulation study so that various proposed solutions could be compared, and final measurements with the final recommended solution in place -supply-side reactors that did not saturate during these surge conditions.\",\"PeriodicalId\":103105,\"journal\":{\"name\":\"2006 IEEE International Conference on Industrial Technology\",\"volume\":\"5 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 IEEE International Conference on Industrial Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIT.2006.372476\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE International Conference on Industrial Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIT.2006.372476","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Failure of LV ASD supply-side fuses due to MV motor fuse operation
Transients in MV networks due to MV motor fuse operation can propagate through MV/LV transformers to LV networks. The LV surges can then cause the high-speed fuses protecting LV adjustable speed drives (ASDs) to operate and this can disrupt production. LV ASDs often include supply-side reactors to make them less susceptible to surges (in particular capacitor-switching surges). For the network studied, these reactors did not prevent operation of the particular ASD highspeed fuses. One possible reason was that the supply-side reactors were saturating during the surge conditions associated with MV fuse operation. This paper describes the investigation that included initial measurements, a simulation study so that various proposed solutions could be compared, and final measurements with the final recommended solution in place -supply-side reactors that did not saturate during these surge conditions.