{"title":"有功配电网和微电网的线性交流三相最优潮流模型","authors":"A. C. de Campos, R. S. Pinto, Mauro O. de Lara Filho, C. Unsihuay-Vila","doi":"10.1109/ISGTLatinAmerica52371.2021.9543035","DOIUrl":null,"url":null,"abstract":"Distribution networks typically have unbalanced loads; however, most works on Active Distribution Networks (ADNs) use single-phase representations. This paper proposes a linear alternate current (AC) three-phase optimal power flow (OPF) for a day-ahead operation planning of ADNs and microgrids. The proposed AC linear three-phase optimal power flow model is based on polar coordinate systems and considering some consistent approximations for linearization of power flow equations. The shunts admittances of the network and the mutual impedances between phases of the three-phase lines are considered in the model. In this paper, the proposed linear AC three-phase OPF model is used to define the optimal day-ahead operation planning of active distribution systems and microgrids with three-phase feeders and three-phase distributed generators (DG) and energy storage (ES). Since this model proposes a three-phase representation of the system, it provides more accurate results, making it an effective tool for optimal planning of the ADN operation. The proposed model is illustrated using the IEEE 34-bus test system and results show its effectiveness and excellent performance, presenting an error of less than 4% for the voltage magnitude of the buses and less than 2% for the apparent power flow of the lines, when compared with non-linear models.","PeriodicalId":120262,"journal":{"name":"2021 IEEE PES Innovative Smart Grid Technologies Conference - Latin America (ISGT Latin America)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Linear AC Three-Phase Optimal Power Flow Model for Active Distribution Networks and Microgrids\",\"authors\":\"A. C. de Campos, R. S. Pinto, Mauro O. de Lara Filho, C. Unsihuay-Vila\",\"doi\":\"10.1109/ISGTLatinAmerica52371.2021.9543035\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Distribution networks typically have unbalanced loads; however, most works on Active Distribution Networks (ADNs) use single-phase representations. This paper proposes a linear alternate current (AC) three-phase optimal power flow (OPF) for a day-ahead operation planning of ADNs and microgrids. The proposed AC linear three-phase optimal power flow model is based on polar coordinate systems and considering some consistent approximations for linearization of power flow equations. The shunts admittances of the network and the mutual impedances between phases of the three-phase lines are considered in the model. In this paper, the proposed linear AC three-phase OPF model is used to define the optimal day-ahead operation planning of active distribution systems and microgrids with three-phase feeders and three-phase distributed generators (DG) and energy storage (ES). Since this model proposes a three-phase representation of the system, it provides more accurate results, making it an effective tool for optimal planning of the ADN operation. The proposed model is illustrated using the IEEE 34-bus test system and results show its effectiveness and excellent performance, presenting an error of less than 4% for the voltage magnitude of the buses and less than 2% for the apparent power flow of the lines, when compared with non-linear models.\",\"PeriodicalId\":120262,\"journal\":{\"name\":\"2021 IEEE PES Innovative Smart Grid Technologies Conference - Latin America (ISGT Latin America)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-09-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE PES Innovative Smart Grid Technologies Conference - Latin America (ISGT Latin America)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISGTLatinAmerica52371.2021.9543035\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE PES Innovative Smart Grid Technologies Conference - Latin America (ISGT Latin America)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGTLatinAmerica52371.2021.9543035","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

配电网通常具有不平衡负载;然而,大多数关于主动配电网络(ADNs)的工作都使用单相表示。本文提出了一种线性交流(AC)三相最优潮流(OPF),用于adn和微电网的日前运行规划。本文提出的交流线性三相最优潮流模型基于极坐标系,并考虑了潮流方程线性化的一致近似。该模型考虑了网络的分流导纳和三相线路的相间互阻抗。本文采用提出的线性交流三相OPF模型,定义了具有三相馈线、三相分布式发电机(DG)和储能(ES)的有源配电系统和微电网的最优日前运行规划。由于该模型提出了系统的三相表示,因此提供了更准确的结果,使其成为ADN运行优化规划的有效工具。利用IEEE 34总线测试系统对该模型进行了验证,结果表明了该模型的有效性和优异性能,与非线性模型相比,母线电压幅值误差小于4%,线路视在潮流误差小于2%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Linear AC Three-Phase Optimal Power Flow Model for Active Distribution Networks and Microgrids
Distribution networks typically have unbalanced loads; however, most works on Active Distribution Networks (ADNs) use single-phase representations. This paper proposes a linear alternate current (AC) three-phase optimal power flow (OPF) for a day-ahead operation planning of ADNs and microgrids. The proposed AC linear three-phase optimal power flow model is based on polar coordinate systems and considering some consistent approximations for linearization of power flow equations. The shunts admittances of the network and the mutual impedances between phases of the three-phase lines are considered in the model. In this paper, the proposed linear AC three-phase OPF model is used to define the optimal day-ahead operation planning of active distribution systems and microgrids with three-phase feeders and three-phase distributed generators (DG) and energy storage (ES). Since this model proposes a three-phase representation of the system, it provides more accurate results, making it an effective tool for optimal planning of the ADN operation. The proposed model is illustrated using the IEEE 34-bus test system and results show its effectiveness and excellent performance, presenting an error of less than 4% for the voltage magnitude of the buses and less than 2% for the apparent power flow of the lines, when compared with non-linear models.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信