基于卡尔曼滤波的有源中性点箝位(ANPC)光伏变流器网络攻击检测

Jinan Zhang, Jin Ye
{"title":"基于卡尔曼滤波的有源中性点箝位(ANPC)光伏变流器网络攻击检测","authors":"Jinan Zhang, Jin Ye","doi":"10.1109/APEC43599.2022.9773382","DOIUrl":null,"url":null,"abstract":"With the upgrading of communication technology, cyber threats to power converters are increasing. In this paper, a model-based cyber-attack detection methodology is proposed for the interleaved Active neutral point clamped (ANPC) Photovoltaic (PV) converter. The proposed methodology identifies cyber-attacks using two estimations based on the Kalman filter and the state-space model of the ANPC PV converter. The residual between the two estimations is analyzed from a statistical perspective. Based on the Cumulative Sum (CUSUM) Control Chart, the standard errors shift of the residual is used to identify cyber-attacks. Besides, to validate the feasibility of the proposed methodology, several conditions are considered in the simulation, including white noise in the sensor, irradiance variation, and cyber-attacks in the PV converter. The simulation result demonstrates the proposed method can identify cyber-attacks in the ANPC PV converter.","PeriodicalId":127006,"journal":{"name":"2022 IEEE Applied Power Electronics Conference and Exposition (APEC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Cyber-Attack Detection for Active Neutral Point Clamped (ANPC) Photovoltaic (PV) Converter using Kalman Filter\",\"authors\":\"Jinan Zhang, Jin Ye\",\"doi\":\"10.1109/APEC43599.2022.9773382\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"With the upgrading of communication technology, cyber threats to power converters are increasing. In this paper, a model-based cyber-attack detection methodology is proposed for the interleaved Active neutral point clamped (ANPC) Photovoltaic (PV) converter. The proposed methodology identifies cyber-attacks using two estimations based on the Kalman filter and the state-space model of the ANPC PV converter. The residual between the two estimations is analyzed from a statistical perspective. Based on the Cumulative Sum (CUSUM) Control Chart, the standard errors shift of the residual is used to identify cyber-attacks. Besides, to validate the feasibility of the proposed methodology, several conditions are considered in the simulation, including white noise in the sensor, irradiance variation, and cyber-attacks in the PV converter. The simulation result demonstrates the proposed method can identify cyber-attacks in the ANPC PV converter.\",\"PeriodicalId\":127006,\"journal\":{\"name\":\"2022 IEEE Applied Power Electronics Conference and Exposition (APEC)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-03-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE Applied Power Electronics Conference and Exposition (APEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APEC43599.2022.9773382\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE Applied Power Electronics Conference and Exposition (APEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEC43599.2022.9773382","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

随着通信技术的升级,对电源转换器的网络威胁日益增加。针对交叉有源中性点箝位(ANPC)光伏(PV)变流器,提出了一种基于模型的网络攻击检测方法。提出的方法使用基于卡尔曼滤波和ANPC光伏变流器状态空间模型的两种估计来识别网络攻击。从统计学的角度分析了两个估计之间的残差。基于累积和(CUSUM)控制图,利用残差的标准误差位移来识别网络攻击。此外,为了验证所提出方法的可行性,在仿真中考虑了几个条件,包括传感器中的白噪声、辐照度变化和PV转换器中的网络攻击。仿真结果表明,该方法能够有效识别ANPC光伏变流器中的网络攻击。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Cyber-Attack Detection for Active Neutral Point Clamped (ANPC) Photovoltaic (PV) Converter using Kalman Filter
With the upgrading of communication technology, cyber threats to power converters are increasing. In this paper, a model-based cyber-attack detection methodology is proposed for the interleaved Active neutral point clamped (ANPC) Photovoltaic (PV) converter. The proposed methodology identifies cyber-attacks using two estimations based on the Kalman filter and the state-space model of the ANPC PV converter. The residual between the two estimations is analyzed from a statistical perspective. Based on the Cumulative Sum (CUSUM) Control Chart, the standard errors shift of the residual is used to identify cyber-attacks. Besides, to validate the feasibility of the proposed methodology, several conditions are considered in the simulation, including white noise in the sensor, irradiance variation, and cyber-attacks in the PV converter. The simulation result demonstrates the proposed method can identify cyber-attacks in the ANPC PV converter.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信