A. Khatib, Anshuman Mallya, Bowen Dai, Roberto Costa
{"title":"案例研究:澳大利亚液化天然气设施的涡轮机负荷分担和减载系统","authors":"A. Khatib, Anshuman Mallya, Bowen Dai, Roberto Costa","doi":"10.1109/PCIC30934.2019.9074511","DOIUrl":null,"url":null,"abstract":"This paper presents a turbine load-sharing and load-shedding system for an islanded liquefied natural gas facility in Australia. The system includes three independent and redundant load-shedding schemes: process-based contingency load shedding with predefined load group and load pairs, high-speed underfrequency-based load shedding, and progressive overload shedding with system frequency supervision. In addition to the load-shedding schemes, the site includes a generation control system with frequency control, voltage control, automatic synchronization, and turbine load-sharing schemes. A breaker-and-a-half configuration complicates the fast load-shedding scheme. Results from hardware-in-the-loop testing are shared.","PeriodicalId":276673,"journal":{"name":"2019 IEEE Petroleum and Chemical Industry Committee Conference (PCIC)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Case Study: Turbine Load-Sharing and Load-Shedding System Foran Australian LNG Facility\",\"authors\":\"A. Khatib, Anshuman Mallya, Bowen Dai, Roberto Costa\",\"doi\":\"10.1109/PCIC30934.2019.9074511\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a turbine load-sharing and load-shedding system for an islanded liquefied natural gas facility in Australia. The system includes three independent and redundant load-shedding schemes: process-based contingency load shedding with predefined load group and load pairs, high-speed underfrequency-based load shedding, and progressive overload shedding with system frequency supervision. In addition to the load-shedding schemes, the site includes a generation control system with frequency control, voltage control, automatic synchronization, and turbine load-sharing schemes. A breaker-and-a-half configuration complicates the fast load-shedding scheme. Results from hardware-in-the-loop testing are shared.\",\"PeriodicalId\":276673,\"journal\":{\"name\":\"2019 IEEE Petroleum and Chemical Industry Committee Conference (PCIC)\",\"volume\":\"3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE Petroleum and Chemical Industry Committee Conference (PCIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PCIC30934.2019.9074511\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE Petroleum and Chemical Industry Committee Conference (PCIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PCIC30934.2019.9074511","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Case Study: Turbine Load-Sharing and Load-Shedding System Foran Australian LNG Facility
This paper presents a turbine load-sharing and load-shedding system for an islanded liquefied natural gas facility in Australia. The system includes three independent and redundant load-shedding schemes: process-based contingency load shedding with predefined load group and load pairs, high-speed underfrequency-based load shedding, and progressive overload shedding with system frequency supervision. In addition to the load-shedding schemes, the site includes a generation control system with frequency control, voltage control, automatic synchronization, and turbine load-sharing schemes. A breaker-and-a-half configuration complicates the fast load-shedding scheme. Results from hardware-in-the-loop testing are shared.