{"title":"不平衡条件下UPFC建模中的动态相量","authors":"P. Stefanov, A. Stanković","doi":"10.1109/ICPST.2000.900116","DOIUrl":null,"url":null,"abstract":"The paper describes an analytical model for unbalanced operation of the unified power flow controller (UPFC). This nonlinear, time-invariant model is expressed in terms of dynamic symmetric components, and it is validated on a benchmark power system example taken from the literature. The model is evaluated via simulations in unbalanced operation and during unbalanced (one phase to ground) faults. The model achieves an accuracy comparable to detailed time-domain models, in addition to a reduction in simulation time.","PeriodicalId":330989,"journal":{"name":"PowerCon 2000. 2000 International Conference on Power System Technology. Proceedings (Cat. No.00EX409)","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Dynamic phasors in modeling of UPFC under unbalanced conditions\",\"authors\":\"P. Stefanov, A. Stanković\",\"doi\":\"10.1109/ICPST.2000.900116\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper describes an analytical model for unbalanced operation of the unified power flow controller (UPFC). This nonlinear, time-invariant model is expressed in terms of dynamic symmetric components, and it is validated on a benchmark power system example taken from the literature. The model is evaluated via simulations in unbalanced operation and during unbalanced (one phase to ground) faults. The model achieves an accuracy comparable to detailed time-domain models, in addition to a reduction in simulation time.\",\"PeriodicalId\":330989,\"journal\":{\"name\":\"PowerCon 2000. 2000 International Conference on Power System Technology. Proceedings (Cat. No.00EX409)\",\"volume\":\"12 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-12-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"PowerCon 2000. 2000 International Conference on Power System Technology. Proceedings (Cat. No.00EX409)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPST.2000.900116\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"PowerCon 2000. 2000 International Conference on Power System Technology. Proceedings (Cat. No.00EX409)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPST.2000.900116","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Dynamic phasors in modeling of UPFC under unbalanced conditions
The paper describes an analytical model for unbalanced operation of the unified power flow controller (UPFC). This nonlinear, time-invariant model is expressed in terms of dynamic symmetric components, and it is validated on a benchmark power system example taken from the literature. The model is evaluated via simulations in unbalanced operation and during unbalanced (one phase to ground) faults. The model achieves an accuracy comparable to detailed time-domain models, in addition to a reduction in simulation time.