{"title":"高亮度和低亮度led在人体组织上的应用,以捕捉指尖的光电体积脉搏图","authors":"R. Shriram, M. Sundhararajan, Nivedita Daimiwal","doi":"10.1109/I2CT.2014.7092340","DOIUrl":null,"url":null,"abstract":"Photoplethysmography (PPG) is the process of applying a light source and photo sensor to an appendage, such as a finger or a toe, and measuring the light that is reflected by the skin. At each contraction of the heart, blood is forced through the peripheral vessels producing engorgement of the vessels under the light source, there by modifying the amount of light reflected to the photo sensor. Arterial pressure is one of the most important physiological parameters for the noninvasive diagnosis and monitoring of cardiovascular diseases. The aim of the project is to develop a reflectance type photoplethysmographic sensor to record the peripheral pulse wave by using various sources. In this study total 21 sources (diffused and clear LEDs) of 3mm and 5mm diameter were used. Opt101 was used as a detector for all the sources and effect the of various sources on PPG in the form of peak-peak voltage was studied. The photoplethysmographic signals are obtained from 8 subjects of different age group and gender. It was seen that the penetration of IR light into the human tissue is more than that of the visible light. Peak-peak voltage of PPG waveform for a clear LED with 3mm diameter was highest than any other LED of the same wavelength and diameter.","PeriodicalId":384966,"journal":{"name":"International Conference for Convergence for Technology-2014","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-04-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Application of high & low brightness LEDs to human tissue to capture photoplethysmogram at a finger tip\",\"authors\":\"R. Shriram, M. Sundhararajan, Nivedita Daimiwal\",\"doi\":\"10.1109/I2CT.2014.7092340\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Photoplethysmography (PPG) is the process of applying a light source and photo sensor to an appendage, such as a finger or a toe, and measuring the light that is reflected by the skin. At each contraction of the heart, blood is forced through the peripheral vessels producing engorgement of the vessels under the light source, there by modifying the amount of light reflected to the photo sensor. Arterial pressure is one of the most important physiological parameters for the noninvasive diagnosis and monitoring of cardiovascular diseases. The aim of the project is to develop a reflectance type photoplethysmographic sensor to record the peripheral pulse wave by using various sources. In this study total 21 sources (diffused and clear LEDs) of 3mm and 5mm diameter were used. Opt101 was used as a detector for all the sources and effect the of various sources on PPG in the form of peak-peak voltage was studied. The photoplethysmographic signals are obtained from 8 subjects of different age group and gender. It was seen that the penetration of IR light into the human tissue is more than that of the visible light. Peak-peak voltage of PPG waveform for a clear LED with 3mm diameter was highest than any other LED of the same wavelength and diameter.\",\"PeriodicalId\":384966,\"journal\":{\"name\":\"International Conference for Convergence for Technology-2014\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-04-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Conference for Convergence for Technology-2014\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/I2CT.2014.7092340\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Conference for Convergence for Technology-2014","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/I2CT.2014.7092340","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

光体积脉搏描记(PPG)是将光源和光传感器应用于附属物(如手指或脚趾)并测量皮肤反射的光的过程。在每次心脏收缩时,血液被强迫通过周围的血管,在光源的照射下,通过改变反射到光传感器上的光量,使血管充血。动脉压是无创诊断和监测心血管疾病最重要的生理参数之一。该项目的目的是开发一种反射型光容积脉搏波传感器,利用各种光源记录周边脉冲波。本研究共使用了21个直径为3mm和5mm的光源(漫射和透明led)。利用Opt101作为所有源的检测器,研究了不同源对PPG的峰值电压形式的影响。不同年龄和性别的8名受试者的光容积脉搏波信号。可见,红外光对人体组织的穿透比可见光要大。直径为3mm的透明LED的PPG波形峰峰电压高于同波长、同直径的其他LED。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Application of high & low brightness LEDs to human tissue to capture photoplethysmogram at a finger tip
Photoplethysmography (PPG) is the process of applying a light source and photo sensor to an appendage, such as a finger or a toe, and measuring the light that is reflected by the skin. At each contraction of the heart, blood is forced through the peripheral vessels producing engorgement of the vessels under the light source, there by modifying the amount of light reflected to the photo sensor. Arterial pressure is one of the most important physiological parameters for the noninvasive diagnosis and monitoring of cardiovascular diseases. The aim of the project is to develop a reflectance type photoplethysmographic sensor to record the peripheral pulse wave by using various sources. In this study total 21 sources (diffused and clear LEDs) of 3mm and 5mm diameter were used. Opt101 was used as a detector for all the sources and effect the of various sources on PPG in the form of peak-peak voltage was studied. The photoplethysmographic signals are obtained from 8 subjects of different age group and gender. It was seen that the penetration of IR light into the human tissue is more than that of the visible light. Peak-peak voltage of PPG waveform for a clear LED with 3mm diameter was highest than any other LED of the same wavelength and diameter.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信