{"title":"电压跌落:它们对公用事业和工业客户的影响","authors":"T. Davis, G. E. Beam, C. Melhorn","doi":"10.1109/ICPS.1996.533938","DOIUrl":null,"url":null,"abstract":"This paper describes the impact of voltage sags on the utility and industrial customers. Several utility measures are presented to minimize the customer's exposure to voltage sags. However, these measures cannot completely eliminate the impact of voltage sags on sensitive equipment. A case study is presented in this paper that includes measurement results that were used to characterize the voltage sags experienced on the utility system and in the industrial facility, simulation results that were used to develop \"area of vulnerability curves\" for the industrial facility, mitigation equipment that was employed to improve the sensitive equipment's ride through capability, and the lessons learned from the systems approach analysis.","PeriodicalId":122944,"journal":{"name":"Proceedings of 1996 IAS Industrial and Commercial Power Systems Technical Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1996-05-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"130","resultStr":"{\"title\":\"Voltage sags: their impact on the utility and industrial customers\",\"authors\":\"T. Davis, G. E. Beam, C. Melhorn\",\"doi\":\"10.1109/ICPS.1996.533938\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes the impact of voltage sags on the utility and industrial customers. Several utility measures are presented to minimize the customer's exposure to voltage sags. However, these measures cannot completely eliminate the impact of voltage sags on sensitive equipment. A case study is presented in this paper that includes measurement results that were used to characterize the voltage sags experienced on the utility system and in the industrial facility, simulation results that were used to develop \\\"area of vulnerability curves\\\" for the industrial facility, mitigation equipment that was employed to improve the sensitive equipment's ride through capability, and the lessons learned from the systems approach analysis.\",\"PeriodicalId\":122944,\"journal\":{\"name\":\"Proceedings of 1996 IAS Industrial and Commercial Power Systems Technical Conference\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-05-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"130\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of 1996 IAS Industrial and Commercial Power Systems Technical Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPS.1996.533938\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 1996 IAS Industrial and Commercial Power Systems Technical Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPS.1996.533938","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Voltage sags: their impact on the utility and industrial customers
This paper describes the impact of voltage sags on the utility and industrial customers. Several utility measures are presented to minimize the customer's exposure to voltage sags. However, these measures cannot completely eliminate the impact of voltage sags on sensitive equipment. A case study is presented in this paper that includes measurement results that were used to characterize the voltage sags experienced on the utility system and in the industrial facility, simulation results that were used to develop "area of vulnerability curves" for the industrial facility, mitigation equipment that was employed to improve the sensitive equipment's ride through capability, and the lessons learned from the systems approach analysis.