Tuan Mohd Ikhwan Bin Tuan Yacob, Z. Zakaria, N. Hamzah
{"title":"六相传输线用自耦变压器变换的研究","authors":"Tuan Mohd Ikhwan Bin Tuan Yacob, Z. Zakaria, N. Hamzah","doi":"10.1109/SCORED.2011.6148736","DOIUrl":null,"url":null,"abstract":"This paper presents the application of an autotransformer for the conversion from three phases to six phase transmission line. The autotransformer with tertiary winding is used to achieve and design consideration in this research. The conversion is tested and simulated using a simple test system which is fed from the source through transmission line about 20km to a power distribution load model. This research focuses on the conversion of the autotransformer and transmission line and measurement to be considered are efficiency, phase angle, waveform current, waveform voltage and the power transfer each phase. The performances of these parameters are presented and discussed.","PeriodicalId":383828,"journal":{"name":"2011 IEEE Student Conference on Research and Development","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Study of six phase transmission line using the autotransformer conversion\",\"authors\":\"Tuan Mohd Ikhwan Bin Tuan Yacob, Z. Zakaria, N. Hamzah\",\"doi\":\"10.1109/SCORED.2011.6148736\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the application of an autotransformer for the conversion from three phases to six phase transmission line. The autotransformer with tertiary winding is used to achieve and design consideration in this research. The conversion is tested and simulated using a simple test system which is fed from the source through transmission line about 20km to a power distribution load model. This research focuses on the conversion of the autotransformer and transmission line and measurement to be considered are efficiency, phase angle, waveform current, waveform voltage and the power transfer each phase. The performances of these parameters are presented and discussed.\",\"PeriodicalId\":383828,\"journal\":{\"name\":\"2011 IEEE Student Conference on Research and Development\",\"volume\":\"10 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 IEEE Student Conference on Research and Development\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SCORED.2011.6148736\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE Student Conference on Research and Development","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SCORED.2011.6148736","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Study of six phase transmission line using the autotransformer conversion
This paper presents the application of an autotransformer for the conversion from three phases to six phase transmission line. The autotransformer with tertiary winding is used to achieve and design consideration in this research. The conversion is tested and simulated using a simple test system which is fed from the source through transmission line about 20km to a power distribution load model. This research focuses on the conversion of the autotransformer and transmission line and measurement to be considered are efficiency, phase angle, waveform current, waveform voltage and the power transfer each phase. The performances of these parameters are presented and discussed.