Anirban Sengupta, Subrat Kumar Pradhan, Dushmanta Kumar Das
{"title":"考虑时变时延的互联电力系统区域间振荡抑制","authors":"Anirban Sengupta, Subrat Kumar Pradhan, Dushmanta Kumar Das","doi":"10.1109/ASPCON49795.2020.9276695","DOIUrl":null,"url":null,"abstract":"A wide area damping controller to mitigate the frequency deviation of interconnected power system is designed in this paper. The test system considered here is a two area power system. Each area in the test system has two generators. A linear matrix inequality (LMI) based state feedback control law is designed with the help of Lyapunov-Krasovskii functional. A thyristor controlled series capacitor (TCSC) is used to provide sufficient damping in the interconnected power system. A supplementary damping controller (SDC) is also used with the TCSC. The effect of time delay in the control signal is also considered in this paper for the two area four machine power system.","PeriodicalId":193814,"journal":{"name":"2020 IEEE Applied Signal Processing Conference (ASPCON)","volume":"62 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Mitigating inter-area oscillation of an interconnected power system considering time varying delay\",\"authors\":\"Anirban Sengupta, Subrat Kumar Pradhan, Dushmanta Kumar Das\",\"doi\":\"10.1109/ASPCON49795.2020.9276695\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A wide area damping controller to mitigate the frequency deviation of interconnected power system is designed in this paper. The test system considered here is a two area power system. Each area in the test system has two generators. A linear matrix inequality (LMI) based state feedback control law is designed with the help of Lyapunov-Krasovskii functional. A thyristor controlled series capacitor (TCSC) is used to provide sufficient damping in the interconnected power system. A supplementary damping controller (SDC) is also used with the TCSC. The effect of time delay in the control signal is also considered in this paper for the two area four machine power system.\",\"PeriodicalId\":193814,\"journal\":{\"name\":\"2020 IEEE Applied Signal Processing Conference (ASPCON)\",\"volume\":\"62 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-10-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE Applied Signal Processing Conference (ASPCON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ASPCON49795.2020.9276695\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE Applied Signal Processing Conference (ASPCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ASPCON49795.2020.9276695","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Mitigating inter-area oscillation of an interconnected power system considering time varying delay
A wide area damping controller to mitigate the frequency deviation of interconnected power system is designed in this paper. The test system considered here is a two area power system. Each area in the test system has two generators. A linear matrix inequality (LMI) based state feedback control law is designed with the help of Lyapunov-Krasovskii functional. A thyristor controlled series capacitor (TCSC) is used to provide sufficient damping in the interconnected power system. A supplementary damping controller (SDC) is also used with the TCSC. The effect of time delay in the control signal is also considered in this paper for the two area four machine power system.