{"title":"生物医学技术服务用x射线照相设备质量控制新方法","authors":"Ahmet Tartar, A. Akan","doi":"10.1109/TIPTEKNO.2016.7863128","DOIUrl":null,"url":null,"abstract":"In the study, a new technical method/protocol is first proposed in the literature for the biomedical technical services. In this context, energy quality control test and focus adjustment test are made for X-ray radiography systems. The method will provide a unique contribution to the application field of the technical services of biomedical and clinical engineering on quality control assessments of radiology equipment.","PeriodicalId":431660,"journal":{"name":"2016 Medical Technologies National Congress (TIPTEKNO)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A new quality control method on X-ray radiography units for biomedical technical service applications\",\"authors\":\"Ahmet Tartar, A. Akan\",\"doi\":\"10.1109/TIPTEKNO.2016.7863128\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the study, a new technical method/protocol is first proposed in the literature for the biomedical technical services. In this context, energy quality control test and focus adjustment test are made for X-ray radiography systems. The method will provide a unique contribution to the application field of the technical services of biomedical and clinical engineering on quality control assessments of radiology equipment.\",\"PeriodicalId\":431660,\"journal\":{\"name\":\"2016 Medical Technologies National Congress (TIPTEKNO)\",\"volume\":\"17 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 Medical Technologies National Congress (TIPTEKNO)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TIPTEKNO.2016.7863128\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 Medical Technologies National Congress (TIPTEKNO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TIPTEKNO.2016.7863128","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A new quality control method on X-ray radiography units for biomedical technical service applications
In the study, a new technical method/protocol is first proposed in the literature for the biomedical technical services. In this context, energy quality control test and focus adjustment test are made for X-ray radiography systems. The method will provide a unique contribution to the application field of the technical services of biomedical and clinical engineering on quality control assessments of radiology equipment.