基于正交多项式的电能质量事件检测与时间定位

U. Dwivedi, Chandrakant Tiwari
{"title":"基于正交多项式的电能质量事件检测与时间定位","authors":"U. Dwivedi, Chandrakant Tiwari","doi":"10.1109/EPETSG.2015.7510103","DOIUrl":null,"url":null,"abstract":"This paper proposes a new and simple approach based on orthogonal polynomial approximation (OPA) to detect, localize, and investigate the feasibility of classification of various types of power quality disturbances. The key idea in this approach is to approximate a given disturbance signal in the least square sense, such that the uncorrelated part (disturbance) of the signal is not present in the approximated version of the signal. It is, therefore, possible to detect and localize power quality (PQ) disturbances by analyzing the difference of the original and approximated signals. This is achieved by choosing the degree of the polynomial using the criterion of minimum error-variance. The effectiveness of the proposed approach is tested and demonstrated to detect and localize PQ disturbances with simulated and actual power line disturbance data.","PeriodicalId":301088,"journal":{"name":"2015 International Conference on Energy, Power and Environment: Towards Sustainable Growth (ICEPE)","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Detection and time localization of power quality events using orthogonal polynomial\",\"authors\":\"U. Dwivedi, Chandrakant Tiwari\",\"doi\":\"10.1109/EPETSG.2015.7510103\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a new and simple approach based on orthogonal polynomial approximation (OPA) to detect, localize, and investigate the feasibility of classification of various types of power quality disturbances. The key idea in this approach is to approximate a given disturbance signal in the least square sense, such that the uncorrelated part (disturbance) of the signal is not present in the approximated version of the signal. It is, therefore, possible to detect and localize power quality (PQ) disturbances by analyzing the difference of the original and approximated signals. This is achieved by choosing the degree of the polynomial using the criterion of minimum error-variance. The effectiveness of the proposed approach is tested and demonstrated to detect and localize PQ disturbances with simulated and actual power line disturbance data.\",\"PeriodicalId\":301088,\"journal\":{\"name\":\"2015 International Conference on Energy, Power and Environment: Towards Sustainable Growth (ICEPE)\",\"volume\":\"40 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-06-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Conference on Energy, Power and Environment: Towards Sustainable Growth (ICEPE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPETSG.2015.7510103\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Energy, Power and Environment: Towards Sustainable Growth (ICEPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPETSG.2015.7510103","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本文提出了一种新的基于正交多项式近似(OPA)的简单方法来检测、定位和研究各种类型电能质量干扰分类的可行性。这种方法的关键思想是在最小二乘意义上近似给定的干扰信号,使得信号的不相关部分(干扰)不存在于信号的近似版本中。因此,可以通过分析原始信号和近似信号的差异来检测和定位电能质量(PQ)干扰。这是通过使用最小误差方差准则选择多项式的程度来实现的。通过模拟和实际的电力线干扰数据,验证了该方法检测和定位PQ干扰的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Detection and time localization of power quality events using orthogonal polynomial
This paper proposes a new and simple approach based on orthogonal polynomial approximation (OPA) to detect, localize, and investigate the feasibility of classification of various types of power quality disturbances. The key idea in this approach is to approximate a given disturbance signal in the least square sense, such that the uncorrelated part (disturbance) of the signal is not present in the approximated version of the signal. It is, therefore, possible to detect and localize power quality (PQ) disturbances by analyzing the difference of the original and approximated signals. This is achieved by choosing the degree of the polynomial using the criterion of minimum error-variance. The effectiveness of the proposed approach is tested and demonstrated to detect and localize PQ disturbances with simulated and actual power line disturbance data.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书