{"title":"血压与脉搏传递时间的相关性研究","authors":"T. Pereira, R. Sanches, P. Reis, J. Pêgo, Ricardo Simões","doi":"10.1109/ENBENG.2015.7088864","DOIUrl":null,"url":null,"abstract":"Blood pressure (BP) determination is a fundamental parameter in cardiovascular assessment. The gold standard method to measure BP is based on the inflatable arm cuff, however has several disadvantages for continuous monitoring. New techniques were developed to overcome these limitations using correlations between the pulse transit time (PTT) and BP. This work draws attention to the PTT rationale using several methods. In order to determine the PTT, an electrocardiogram (ECG) was used combined with multiple photoplethysmography (PPG) sensors applied to different arm locations, these signals were acquired with a bioPLUX device. The Ultrassound system (SonoSite Edge) was used to measure the artery diameter. As reference, BP was measured using a cuff-based sphygmomanometric device. Measurements were performed in a study population of 36 volunteers. The correlation coefficient for DBP determined and DBP measured was r = 0,689. The results suggest PTT deduced from different locations can be used to measure BP.","PeriodicalId":285567,"journal":{"name":"2015 IEEE 4th Portuguese Meeting on Bioengineering (ENBENG)","volume":"23 4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-04-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Correlation study between blood pressure and pulse transit time\",\"authors\":\"T. Pereira, R. Sanches, P. Reis, J. Pêgo, Ricardo Simões\",\"doi\":\"10.1109/ENBENG.2015.7088864\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Blood pressure (BP) determination is a fundamental parameter in cardiovascular assessment. The gold standard method to measure BP is based on the inflatable arm cuff, however has several disadvantages for continuous monitoring. New techniques were developed to overcome these limitations using correlations between the pulse transit time (PTT) and BP. This work draws attention to the PTT rationale using several methods. In order to determine the PTT, an electrocardiogram (ECG) was used combined with multiple photoplethysmography (PPG) sensors applied to different arm locations, these signals were acquired with a bioPLUX device. The Ultrassound system (SonoSite Edge) was used to measure the artery diameter. As reference, BP was measured using a cuff-based sphygmomanometric device. Measurements were performed in a study population of 36 volunteers. The correlation coefficient for DBP determined and DBP measured was r = 0,689. The results suggest PTT deduced from different locations can be used to measure BP.\",\"PeriodicalId\":285567,\"journal\":{\"name\":\"2015 IEEE 4th Portuguese Meeting on Bioengineering (ENBENG)\",\"volume\":\"23 4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-04-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE 4th Portuguese Meeting on Bioengineering (ENBENG)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ENBENG.2015.7088864\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE 4th Portuguese Meeting on Bioengineering (ENBENG)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ENBENG.2015.7088864","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Correlation study between blood pressure and pulse transit time
Blood pressure (BP) determination is a fundamental parameter in cardiovascular assessment. The gold standard method to measure BP is based on the inflatable arm cuff, however has several disadvantages for continuous monitoring. New techniques were developed to overcome these limitations using correlations between the pulse transit time (PTT) and BP. This work draws attention to the PTT rationale using several methods. In order to determine the PTT, an electrocardiogram (ECG) was used combined with multiple photoplethysmography (PPG) sensors applied to different arm locations, these signals were acquired with a bioPLUX device. The Ultrassound system (SonoSite Edge) was used to measure the artery diameter. As reference, BP was measured using a cuff-based sphygmomanometric device. Measurements were performed in a study population of 36 volunteers. The correlation coefficient for DBP determined and DBP measured was r = 0,689. The results suggest PTT deduced from different locations can be used to measure BP.