由光学传感器网络记录的泄漏电流脉冲的长期分析

Leandro H. S. Silva, S. C. Oliveira, Ricardo Ataide de Lima, E. Fontana
{"title":"由光学传感器网络记录的泄漏电流脉冲的长期分析","authors":"Leandro H. S. Silva, S. C. Oliveira, Ricardo Ataide de Lima, E. Fontana","doi":"10.1109/IMOC.2013.6646584","DOIUrl":null,"url":null,"abstract":"The loss of insulation capacity caused by pollution deposition on insulator strings can be inferred from the analysis of the electric arcs due to partial discharges on the insulators. The partial discharges also cause pulses superposed to the leakage current signal. An optical sensor system network was developed and installed in the northeast region of Brazil to monitor the degree of pollution deposited over insulator strings of high voltage transmission lines. The monitoring system comprises leakage, humidity and temperature sensors, a processing electronic module and a satellite communication link. They were installed on 230 and 500 kV towers. This paper presents a correlation study comparing the information obtained from the monitoring systems and the electric arc levels obtained by traditional visual inspections. Also the rain events influence the leakage current behavior and a rain pattern recognition system is used in order to better evaluate the leakage current behavior.","PeriodicalId":395359,"journal":{"name":"2013 SBMO/IEEE MTT-S International Microwave & Optoelectronics Conference (IMOC)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Long term analysis of leakage current pulses registered by an optical sensor network\",\"authors\":\"Leandro H. S. Silva, S. C. Oliveira, Ricardo Ataide de Lima, E. Fontana\",\"doi\":\"10.1109/IMOC.2013.6646584\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The loss of insulation capacity caused by pollution deposition on insulator strings can be inferred from the analysis of the electric arcs due to partial discharges on the insulators. The partial discharges also cause pulses superposed to the leakage current signal. An optical sensor system network was developed and installed in the northeast region of Brazil to monitor the degree of pollution deposited over insulator strings of high voltage transmission lines. The monitoring system comprises leakage, humidity and temperature sensors, a processing electronic module and a satellite communication link. They were installed on 230 and 500 kV towers. This paper presents a correlation study comparing the information obtained from the monitoring systems and the electric arc levels obtained by traditional visual inspections. Also the rain events influence the leakage current behavior and a rain pattern recognition system is used in order to better evaluate the leakage current behavior.\",\"PeriodicalId\":395359,\"journal\":{\"name\":\"2013 SBMO/IEEE MTT-S International Microwave & Optoelectronics Conference (IMOC)\",\"volume\":\"24 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-10-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 SBMO/IEEE MTT-S International Microwave & Optoelectronics Conference (IMOC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IMOC.2013.6646584\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 SBMO/IEEE MTT-S International Microwave & Optoelectronics Conference (IMOC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMOC.2013.6646584","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

通过对绝缘子局部放电产生的电弧的分析,可以推断出绝缘子串上污染沉积引起的绝缘容量损失。局部放电也会引起脉冲叠加到泄漏电流信号上。为了监测高压输电线路绝缘子串上的污染程度,在巴西东北部地区开发并安装了一个光学传感器系统网络。监测系统包括泄漏、湿度和温度传感器、处理电子模块和卫星通信链路。它们被安装在230千伏和500千伏的塔上。本文对监测系统获得的信息与传统目视检测得到的电弧水平进行了相关性研究。降雨事件也会影响漏电流的行为,为了更好地评估漏电流的行为,采用了降雨模式识别系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Long term analysis of leakage current pulses registered by an optical sensor network
The loss of insulation capacity caused by pollution deposition on insulator strings can be inferred from the analysis of the electric arcs due to partial discharges on the insulators. The partial discharges also cause pulses superposed to the leakage current signal. An optical sensor system network was developed and installed in the northeast region of Brazil to monitor the degree of pollution deposited over insulator strings of high voltage transmission lines. The monitoring system comprises leakage, humidity and temperature sensors, a processing electronic module and a satellite communication link. They were installed on 230 and 500 kV towers. This paper presents a correlation study comparing the information obtained from the monitoring systems and the electric arc levels obtained by traditional visual inspections. Also the rain events influence the leakage current behavior and a rain pattern recognition system is used in order to better evaluate the leakage current behavior.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信