{"title":"利用MATLAB/Simulink进行高压灭菌器仿真设计与分析","authors":"Betül Altinsu, Onur Kocak, Ali Akpek","doi":"10.1109/TIPTEKNO.2016.7863081","DOIUrl":null,"url":null,"abstract":"The aim of this study is to make simulations with Matlab/Simulink to be used in the production phase of the autoclave in the sterilization unit. Sterilization unit is very important in terms of hospital employees and patients for protecting from infections and accidents. The study examined autoclave equipments that are fabricated based on the EN standards, then mathematical calculations were performed by 1the references obtained from these calculations. These references transferred as the necessary characteristics for MATLAB/Simulink modelling. By analyzing these characteristics, the impact of the variations throughout the production or development pahese can be predicted by investigating the changes in these characteristics. After this study, it is anticipated to convet this model into prototypes and obtain more tangible result. In this study, embedded sytems are used and the data is transferred to an electronic media. Later, the system will be tested on one of the autoclaves that is currently available on the market. It is planned that by exchanging the mainboard of the autoclave with another mainbored which the new software has installed and inspected on the device, afterwards.","PeriodicalId":431660,"journal":{"name":"2016 Medical Technologies National Congress (TIPTEKNO)","volume":"124 1-3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Design and analysis of an autoclave simulation using MATLAB/Simulink\",\"authors\":\"Betül Altinsu, Onur Kocak, Ali Akpek\",\"doi\":\"10.1109/TIPTEKNO.2016.7863081\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The aim of this study is to make simulations with Matlab/Simulink to be used in the production phase of the autoclave in the sterilization unit. Sterilization unit is very important in terms of hospital employees and patients for protecting from infections and accidents. The study examined autoclave equipments that are fabricated based on the EN standards, then mathematical calculations were performed by 1the references obtained from these calculations. These references transferred as the necessary characteristics for MATLAB/Simulink modelling. By analyzing these characteristics, the impact of the variations throughout the production or development pahese can be predicted by investigating the changes in these characteristics. After this study, it is anticipated to convet this model into prototypes and obtain more tangible result. In this study, embedded sytems are used and the data is transferred to an electronic media. Later, the system will be tested on one of the autoclaves that is currently available on the market. It is planned that by exchanging the mainboard of the autoclave with another mainbored which the new software has installed and inspected on the device, afterwards.\",\"PeriodicalId\":431660,\"journal\":{\"name\":\"2016 Medical Technologies National Congress (TIPTEKNO)\",\"volume\":\"124 1-3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 Medical Technologies National Congress (TIPTEKNO)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TIPTEKNO.2016.7863081\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 Medical Technologies National Congress (TIPTEKNO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TIPTEKNO.2016.7863081","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Design and analysis of an autoclave simulation using MATLAB/Simulink
The aim of this study is to make simulations with Matlab/Simulink to be used in the production phase of the autoclave in the sterilization unit. Sterilization unit is very important in terms of hospital employees and patients for protecting from infections and accidents. The study examined autoclave equipments that are fabricated based on the EN standards, then mathematical calculations were performed by 1the references obtained from these calculations. These references transferred as the necessary characteristics for MATLAB/Simulink modelling. By analyzing these characteristics, the impact of the variations throughout the production or development pahese can be predicted by investigating the changes in these characteristics. After this study, it is anticipated to convet this model into prototypes and obtain more tangible result. In this study, embedded sytems are used and the data is transferred to an electronic media. Later, the system will be tested on one of the autoclaves that is currently available on the market. It is planned that by exchanging the mainboard of the autoclave with another mainbored which the new software has installed and inspected on the device, afterwards.