Q. Tao, M. V. D. Giessen, Sebastiaan R. Piers, K. Zeppenfeld, R. Geest
{"title":"结合磁共振晚期钆增强和Look-Locker序列对心肌疤痕的表征","authors":"Q. Tao, M. V. D. Giessen, Sebastiaan R. Piers, K. Zeppenfeld, R. Geest","doi":"10.1109/ISBI.2013.6556479","DOIUrl":null,"url":null,"abstract":"Characterization of myocardial scar has important diagnostic and prognostic value for treatment of post-infarction patients. Late gadolinium enhanced (LGE) MR visualizes myocardial scar as regions of hyper-enhanced signal intensity, however, the accuracy and reproducibility of scar characterization is impaired by the lack of an absolute measure in this imaging modality. We propose a new method to calibrate the signal intensity of LGE MR using the accompanying Look-Locker (LL) MR sequence which measures the absolute tissue T1 relaxation properties. The calibrated LGE MR results in accurate scar characterization, as demonstrated by comparison with high-density electroanatomic voltage mapping (EAVM) data acquired during a ventricular tachycardia (VT) ablation procedure in a group of 15 post-infarction patients.","PeriodicalId":178011,"journal":{"name":"2013 IEEE 10th International Symposium on Biomedical Imaging","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Combining magnetic resonance late gadolinium enhanced and Look-Locker sequences for myocardial scar characterization\",\"authors\":\"Q. Tao, M. V. D. Giessen, Sebastiaan R. Piers, K. Zeppenfeld, R. Geest\",\"doi\":\"10.1109/ISBI.2013.6556479\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Characterization of myocardial scar has important diagnostic and prognostic value for treatment of post-infarction patients. Late gadolinium enhanced (LGE) MR visualizes myocardial scar as regions of hyper-enhanced signal intensity, however, the accuracy and reproducibility of scar characterization is impaired by the lack of an absolute measure in this imaging modality. We propose a new method to calibrate the signal intensity of LGE MR using the accompanying Look-Locker (LL) MR sequence which measures the absolute tissue T1 relaxation properties. The calibrated LGE MR results in accurate scar characterization, as demonstrated by comparison with high-density electroanatomic voltage mapping (EAVM) data acquired during a ventricular tachycardia (VT) ablation procedure in a group of 15 post-infarction patients.\",\"PeriodicalId\":178011,\"journal\":{\"name\":\"2013 IEEE 10th International Symposium on Biomedical Imaging\",\"volume\":\"37 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-04-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE 10th International Symposium on Biomedical Imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISBI.2013.6556479\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE 10th International Symposium on Biomedical Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISBI.2013.6556479","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Combining magnetic resonance late gadolinium enhanced and Look-Locker sequences for myocardial scar characterization
Characterization of myocardial scar has important diagnostic and prognostic value for treatment of post-infarction patients. Late gadolinium enhanced (LGE) MR visualizes myocardial scar as regions of hyper-enhanced signal intensity, however, the accuracy and reproducibility of scar characterization is impaired by the lack of an absolute measure in this imaging modality. We propose a new method to calibrate the signal intensity of LGE MR using the accompanying Look-Locker (LL) MR sequence which measures the absolute tissue T1 relaxation properties. The calibrated LGE MR results in accurate scar characterization, as demonstrated by comparison with high-density electroanatomic voltage mapping (EAVM) data acquired during a ventricular tachycardia (VT) ablation procedure in a group of 15 post-infarction patients.